AC Contact Rating - Relay | 1 A AC-15, 3 A AC-1, 3 A AC-15, 5 A AC-1 |
DC Contact Rating - Relay | 5 A DC-1, 3 A DC-13, 3 A DC-1, 1 A DC-13 |
Mounting - Relay | DIN Rail |
Input Power Consumption (Burden) | 2 W |
Delay Time - Relay | Sync time between inputs: 0.5s 2s 4 s |
Overall Height - Relay | 3.94 in |
Mounting Style | DIN Rail |
Overall Depth | 3.9 in |
Body Depth - Relay | 4.72 in |
Width | 22.5 mm |
Height | 100 mm |
Body Height - Relay | 3.94 in |
For Use With | Emergency Stop, Guard Switch, Magnetic Switch, PNP Sensors, Proximity Safety Switch, RFID Safety Switch, Safety Light Curtain, Two Hand Control Station or Enabling Switch |
Body Width - Relay | 0.89 in |
Standards | CCC, cULus Listed, EAC, IEC 60947-5-1, IEC 61508-1/2/3, IEC 62061, ISO 13849-1, TUV Certified |
Response Time | 20 msec |
IP Rating | IP20, IP40, IP54 |
Depth | 120 mm |
Environmental Protection | Dust & Splash Resistant |
Item | Force |
Power Consumption | 2 W |
Application | Emergency Stops |
Input Voltage | 24V AC/DC |
Electrical Connection - Relay | Screw Terminal, Terminal Block Removable |
Weight | 7.05 oz |
Delay Type | Adjustable |
Frequency | 50/60 Hz |
Delay Time | 0.5 sec, 2 sec, 4 sec |
Body Height | 3.94 in |
Body Width | 0.89 in |
Electrical Connection Type | Screw |
Safety Reliability Data | Dcavg Greater Than= 99% Conforming to ISO 13849-1, HFT = 1 Conforming to IEC 61508-1, HFT = 1 Conforming to IEC 62061, MTTFd Greater Than 30 years Conforming to ISO 13849-1, PFHd = 1.13E-09 Conforming to IEC 61508-1, PFHd = 1.13E-09 Conforming to IEC 62061, PFHd = 1.13E-09 Conforming to ISO 13849-1, SFF Greater Than 99% Conforming to IEC 61508-1, SFF Greater Than 99% Conforming to IEC 62061, Type = B Conforming to IEC 61508-1 |
Maximum Operating Temperature | 185 Degrees F |
Number of Inputs | 2 |
Contact Rating (AC) | 1 A @ 15V (NC), 3 A @ 1V (NC), 3 A @ 15V (NO), 5 A @ 1V (NO) |
Number of Input Channels | 2 |
Body Depth | 4.72 in |
Electrical Connection | Screw Terminal, Terminal Block Removable |
Relay Mounting Style | DIN-Rail |
Minimum Operating Temperature | -13 Degrees F |
Contact Rating (DC) | 1 A @ 13V (NC), 3 A @ 1V (NC), 3 A @ 13V (NO), 5 A @ 1V (NO) |
[Ith] Conventional Free Air Thermal Current | 8A |
Mounting Support | 35 mm symmetrical DIN rail |
Connections - Terminals | removable screw terminal block, 0.2...2.5 mm? solid or flexible || removable screw terminal block, 0.25...2.5 mm? flexible with ferrule single conductor || removable screw terminal block, 0.2...1.5 mm? solid or flexible twin conductor || removable screw terminal block, 2 x 0.25...1 mm? flexible with ferrule without cable end, with bezel || removable screw terminal block, 2 x 0.5...1.5 mm? flexible with ferrule with cable end, with bezel |
Product Or Component Type | safety module |
Input/Output Type | semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related |
[Ui] Rated Insulation Voltage | 250 V 2)EN/IEC 60947-1 |
Power Consumption In Va | 5.0 VA 24 V AC 50/60 Hz |
Auxiliary Contact Composition | 2 NO |
Ip Degree Of Protection | IP20 terminals)EN/IEC 60529 || IP40 housing)EN/IEC 60529 || IP54 mounting area)EN/IEC 60529 |
Minimum Output Voltage | 12 V relay output |
Local Signalling | for power ON LED (green) || for error LED (red) || for safety output status LED (yellow) || for start input LED (yellow) || for safety input S12 LED (yellow) || for safety input S13 LED (yellow) || for safety input S22 LED (yellow) || for safety input S23 LED (yellow) |
Electrical Circuit Type | NC pair || PNP pair || antivalent pair || OSSD pair |
Power Consumption In W | 2 W 24 V DC |
Maximum Response Time On Input Open | 20 ms |
Safety Module Application | for electrical monitoring of two-hand control stations || monitoring antivalent contacts || for emergency stop, guard and light curtain monitoring || for enabling switch monitoring |
Safety Module Name | XPSUS |
Safety Level | can reach PL e/category 4 ISO 13849-1 || can reach SILCL 3 IEC 62061 || can reach SIL 3 IEC 61508 |
Synchronisation Time Between Inputs | 0.5 s || 2 s || 4 s |
Maximum Line Resistance | 500 Ohm |
Ambient Air Temperature For Storage | -25-85°C |
Product Certifications | TUV || cULus |
Input Protection Type | internal, electronic |
Function Of Module | emergency stop button with 2 NC contacts || guard monitoring with 1 or 2 limit switches || monitoring 2 PNP sensors || magnetic switch monitoring || light curtain monitoring || RFID switch || monitoring of electro-sensitive protection equipment (ESPE) || enabling switch monitoring || proximity sensor monitoring || monitoring two-hand control station |
Associated Fuse Rating | 10 A gG NO relay output circuit IEC 60947-1 |
Input Compatibility | normally closed circuit ISO 14119 || XC limit switch ISO 14119 || mechanical contact ISO 14119 || normally closed circuit ISO 13850 || antivalent pair ISO 14119 || OSSD pair IEC 61496-1-2 || two-hand control EN 574/ISO 13851-III A || two-hand control EN 574/ISO 13851-III C || 3-wire proximity sensors PNP |
[Ie] Rated Operational Current | 5 A AC-1 for normally open relay contact || 3 A AC-15 for normally open relay contact || 5 A DC-1 for normally open relay contact || 3 A DC-13 for normally open relay contact || 3 A AC-1 for normally closed relay contact || 1 A AC-15 for normally closed relay contact || 3 A DC-1 for normally closed relay contact || 1 A DC-13 for normally closed relay contact |
[Uimp] Rated Impulse Withstand Voltage | 4 kV II EN/IEC 60947-1 |
Relative Humidity | 5-95 % non-condensing |
Number Of Outputs | 3 on/off configurable pulsed output |
[Us] Rated Supply Voltage | 24 V AC - 15...10 % || 24 V DC - 20...20 % |
Type Of Start | automatic/manual/monitored |
Minimum Output Current | 10 mA relay output |
Country of Origin (subject to change) | Indonesia |
Package Quantity | 1 |
Force, DIN Rail, 4.72" D, 3.94" H, 0.89"W, 2W, SCHNEIDER, Mfr# XPSUS12AP
$316,99
Free shipping will be applied on orders over $50
Force, Delay Time 0.5 sec, 2 sec, 4 sec, Delay Type Adjustable, Electrical Connection Screw Terminal, Terminal Block Removable, IP Rating IP20; IP40; IP54, Input Voltage 24V AC/DC, Mounting Style DIN Rail, Number of Inputs 2, Response Time 20 msec, Standards CCC, cULus Listed, EAC, IEC 60947-5-1, IEC 61508-1/2/3, IEC 62061, ISO 13849-1, TUV Certified, Contact Rating (AC) 1 A @ 15V (NC), 3 A @ 1V (NC), 3 A @ 15V (NO), 5 A @ 1V (NO)
9999 in stock
Must order in multiples of 1
Subtotal:
$316.99
You must be logged in to post a review.
Reviews
There are no reviews yet.