Full Load Amps-Inductive | 50 A |
Item | IEC Magnetic Contactor |
Full Load Amps-Resistive | 80 A |
Number of Poles | 3 |
Coil Volts | 220 V AC |
HP @ 1 Phase - 240V | 7 1/2 hp |
Height | 122 mm |
HP @ 3 Phase - 208V | 15 hp |
Width | 55 mm |
HP @ 3 Phase - 575V | 40 hp |
HP @ 3 Phase - 240V | 15 hp |
Depth | 120 mm |
HP @ 3 Phase - 480V | 40 hp |
Aux. Contact Configuration | 1NO/1NC |
Includes | Everlink Power Connections |
Standards | CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, RINA, DNV, CSA, GOST, BV, GL, UL, CCC, LROS, THIEC 60068-2-30 |
Series | LC1D |
Application | Motor Control, Resistive Load |
Features | Without Built-In Suppressor Module |
Fire Rating | UL 94 V1 |
Mounts On | Plate, Rail |
Switching Current | 5 mA (Signalling Circuit) |
Mechanical Durability | 6 Mcycles |
Signalling Circuit Frequency | 25 to 400 Hz |
Impedance | 1.5 mOhm |
Rated Breaking Capacity | 900 A @ 440V |
Operating Speed | 3600 cycles per hr |
Tightening Torque | 1.7 Nm (Control Circuit), 2.5 to 8 Nm (Power Circuit) |
Control Circuit Voltage Limits | Drop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz) |
Hold VA | 13 VA (at 60 Hz 20°C), 15 VA (at 50 Hz 20°C) |
Rated Voltage | 690V AC, 300V DC |
Switching Voltage | 17 V (Signalling Circuit) |
Fuse Amps | 10 A (Signalling Circuit), 100 A (Type 1 Power Circuit), 100 A (Type 2 Power Circuit) |
Net Weight | 0.855 kg |
Includes Protective Cover | Yes |
Rated Insulation Volts | 600/690V |
Environmental Attributes | Mercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3 |
Electrical Durability | 1.45 Mcycles (50 A, AC-3, Less than 440 V), 1.1 Mcycles (80 A, AC-1, Less than 440 V), 1.45 Mcycles (50 A, AC-3e, Less than 440 V) |
Max. Temperature | 850°C |
Electrical Connection | Control Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors |
Overvoltage Category | CAT III |
Watts Loss | 4 to 5W |
Non-Overlap Time | 1.5 ms |
Operating Time | 4 to 19 ms (Opening), 12 to 26 ms (Closing) |
IP Rating | IP20 |
Working Height | Up to 9842.52 ft |
Impulse Withstand Voltage | 6 kV |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Shock Resistance | 10 G for 11 ms (Contactor Open), 15 G for 11 ms (Contactor Closed) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Inrush VA | 140 VA (at 60 Hz 20°C), 160 VA (at 50 Hz 20°C) |
Thermal Amperage | 10 A (at 60°C Signalling Circuit), 80 A (at 60°C Power Circuit) |
Rated Short-Time Withstand Current | 400 A (at 40°C for 10 s Power Circuit), 810 A (at 40°C for 1 s Power Circuit), 84 A (at 40°C for 10 min Power Circuit), 208 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit) |
Rated Making Capacity | 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 900 A @ 440V (Power Circuit) |
Max. Operating Watts | 15 kW (at 220 to 230V AC 50/60 Hz AC-3), 22 kW (at 380 to 400V AC 50/60 Hz AC-3), 30 kW (at 500V AC 50/60 Hz AC-3), 33 kW (at 660 to 690V AC 50/60 Hz AC-3), 25 kW (at 415V AC 50/60 Hz AC-3), 30 kW (at 440V AC 50/60 Hz AC-3), 11 kW (at 400V AC 50/60 Hz AC-4), 15 kW (at 220 to 230V AC 50/60 Hz AC-3e), 22 kW (at 380 to 400V AC 50/60 Hz AC-3e), 30 kW (at 500V AC 50/60 Hz AC-3e), 33 kW (at 660 to 690V AC 50/60 Hz AC-3e), 25 kW (at 415V AC 50/60 Hz AC-3e), 30 kW (at 440V AC 50/60 Hz AC-3e) |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 220 V AC, 50 A, SCHNEIDER ELECTRIC, Mfr# LC1D50AM7
$276,99
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Number of Poles 3
9999 in stock
Must order in multiples of 1
Subtotal:
$276.99
You must be logged in to post a review.
Reviews