IEC Magnetic Contactor, 4 Poles, 120 V AC, 18 A, SCHNEIDER ELECTRIC, Mfr# LC1D188G7

$190,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor

9999 in stock

Must order in multiples of 1
Subtotal:
$190.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D188G7
Availability: Ships in 5 days
SKU: GRG0569199 Category:

Analogues

ItemIEC Magnetic Contactor
Full Load Amps-Inductive18 A
Number of Poles4
Coil Volts120 V AC
Height91 mm
Width45 mm
Depth99 mm
Aux. Contact Configuration1NO/1NC
StandardsEN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 60947-4-1, UL 60947-5-1, CSA C22.2 No 60947-4-1, CSA C22.2 No 60947-5-1, GB/T 14048.4, UL, CSA, CCC, EAC, UKCA, CB, EU-RO-MR by DNV-GL, THIEC 60068-2-30
SeriesLC1D
IP RatingIP20
Thermal Amperage10 A (at 60°C Signalling Circuit), 32 A (at 60°C Power Circuit)
Electrical Durability1 Mcycles (32 A, AC-1, Less than 440 V)
Electrical ConnectionScrew Clamp Terminals
Inrush VA70 VA
Rated Insulation Volts600/690V
Signalling Circuit Frequency25 to 400 Hz
Rated Breaking Capacity300 A @ 440V
Tightening Torque1.7 Nm (Control Circuit), 1.8 Nm (Power Circuit)
Mounts OnPlate, Rail
Watts Loss2 to 3W
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 60°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz)
Operating Speed3600 cycles per hr
Rated Voltage690V AC
FeaturesWithout Built-In Suppressor Module
Rated Making Capacity140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit), 300 A @ 440V (Power Circuit)
Impulse Withstand Voltage6 kV
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Switching Voltage17 V (Signalling Circuit)
Max. Temperature850°C
Working HeightUp to 9842.52 ft
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Non-Overlap Time1.5 ms
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Overvoltage CategoryCAT III
Mechanical Durability15 Mcycles
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
Includes Protective CoverYes
ApplicationResistive Load
Fuse Amps10 A (Signalling Circuit), 50 A (Type 1 Power Circuit), 35 A (Type 2 Power Circuit)
Net Weight0.425 kg
Switching Current5 mA (Signalling Circuit)
Rated Short-Time Withstand Current145 A (at 40°C for 10 s Power Circuit), 240 A (at 40°C for 1 s Power Circuit), 40 A (at 40°C for 10 min Power Circuit), 84 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Impedance2.5 mOhm
Fire RatingUL 94 V1
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Connections - TerminalsControl circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 10 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.02 in? (2.5 to 16 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.02 in? (2.5 to 16 mm?) - cable stiffness: solid without cable end
Protective TreatmentTHIEC 60068-2-30
Contact CompatibilityM6
Pole Contact Composition2 NO + 2 NC
Rated Operational Current32 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit
Flame RetardanceV1 conforming to UL 94
IRMS Rated Making Capacity140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 300 A at 440 V for power circuit conforming to IEC 60947
Power Dissipation Per Pole2.5 W AC-1
Rated Short Time Withstand Current145 A 104°F (40°C) - 10 s for power circuit, 240 A 104°F (40°C) - 1 s for power circuit, 40 A 104°F (40°C) - 10 min for power circuit, 84 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Product Or Component TypeContactor
Conventional Free Air Thermal Current10 A (at 140°F (60°C)) for signalling circuit, 32 A (at 140°F (60°C)) for power circuit
Poles Description4P
Heat Dissipation2 to 3 W at 50/60 Hz
Hold-In Power Consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Control Circuit TypeAC 50/60 Hz
Minimum Switching Current5 mA for signalling circuit
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz
Rated Impulse Withstand Voltage6 kV IEC 60947
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 50 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 35 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Auxiliary Contact Composition1 NO + 1 NC
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Mounting SupportRail, Plate
Pollution Degree3
Protective CoverWith
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor open 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms)
Product CertificationsUL, CSA, CCC, EAC, UKCA, CB, EU-RO-MR by DNV-GL
Average Impedance2.5 mOhm - Ith 32 A 50 Hz for power circuit
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Inrush Power in VA70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Minimum Switching Voltage17 V for signalling circuit
Control Circuit Voltage120 V AC 50/60 Hz
Utilisation CategoryAC-1, AC-3, AC-3e, AC-4
IP Degree Of ProtectionIP20 front face IEC 60529
Fire Resistance1562°F (850°C) IEC 60695-2-1
Country of Origin (subject to change)Multiple
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#4 Poles
#120 V AC
#18 A
#SCHNEIDER ELECTRIC
#Mfr LC1D188G7
#SCHNEIDER ELECTRIC
#GRG0569199
#mfr:LC1D188G7
#part number:LC1D188G7
#pn:LC1D188G7
#part code:LC1D188G7
#item number:LC1D188G7
#product code:LC1D188G7
#manufacturer number:LC1D188G7
#manufacturers part number:LC1D188G7
#mfn:LC1D188G7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!