IEC Magnetic Contactor, 3 Poles, 100 to 250 V AC/DC, 40 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LC1D40AKUE

$107,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO/1NC, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 100-250V AC/DC, Number of Poles 3, Full Load Current - Inductive 40 A, Full Load Current - Resistive 60 A, Reversing Capability Non-Reversing, Overall Height 4.8 in, Overall Width 2.17 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys Deca, Number of Auxillary Contacts 2, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$107.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D40AKUE
Availability: Ships in 5 days
SKU: GRG6542273 Category:

Analogues

ItemIEC Magnetic Contactor
Full Load Amps-Inductive40 A
Full Load Amps-Resistive60 A
Number of Poles3
Coil Volts100 to 250 V AC/DC
ReversingNo
HP @ 1 Phase - 120V3 hp
HP @ 1 Phase - 240V5 hp
Height4.8 in
Width2.17 in
HP @ 3 Phase - 208V10 hp
HP @ 3 Phase - 575V30 hp
Depth4.72 in
HP @ 3 Phase - 240V10 hp
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V30 hp
Aux. Contact Configuration1NO/1NC
Hz50/60
Frame / Series / Class / CodeTeSys
StandardsCCC, CSA, CSA C22.2 No 60947-4-1, DNV-GL, EAC, EN/IEC 60947-4-1, EN/IEC 60947-5-1, IEC 60335-1, KC, LROS, UKCA, UL Listed, UL 60947-4-1
Auxiliary Contact Form1NO/1NC
SeriesTeSys Deca
NEMA SizeNot Applicable
IncludesEverlink Power Connections
Inrush VA18 VA
Net Weight0.992 kg
Impedance1.5 mOhm
Hold VA1.8 VA
Impulse Withstand Voltage6 kV
Overvoltage CategoryCAT III
Operating Speed3600 cycles per hr
Electrical ConnectionControl Circuit: Screw Clamp Terminals, Power Circuit: EverLink BTR Screw Connectors
Control Circuit Voltage LimitsDrop-Out AC/DC: Less Than 0.1 Uc (at -40 to 70°C), Operational AC/DC: 0.85 to 1.1 Uc (at -40 to 60°C), 1 to 1.1 Uc (at 60 to 70°C)
Operating Time55 to 65 ms (Closing), 20 to 120 ms (Opening)
Thermal Amperage60 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit)
FeaturesBuilt-In Bi-Directional Peak Limiting
Fuse Amps80 A (Type 1 and 2 Power Circuit), 10 A (Signalling Circuit)
ApplicationMotor Control, Resistive Load
Rated Insulation Volts690V
Signalling Circuit Frequency25 to 400 Hz
Tightening Torque1.7 Nm (Control Circuit), 5 to 8 Nm (Power Circuit)
Rated Breaking Capacity800 A @ 440V
Mechanical Durability6 Mcycles
Fire RatingUL 94 V1
Environmental AttributesMercury Free, Pollution Degree 3
IP RatingIP20
Rated Making Capacity800 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Max. Operating Watts11 kW (at 220 to 230V AC 50 Hz AC-3), 18.5 kW (at 380 to 400V AC 50 Hz AC-3), 22 kW (at 415V AC 50 Hz AC-3), 22 kW (at 440V AC 50 Hz AC-3), 22 kW (at 500V AC 50 Hz AC-3), 30 kW (at 660 to 690V AC 50 Hz AC-3), 11 kW (at 220 to 230V AC 50 Hz AC-3e), 18.5 kW (at 380 to 400V AC 50 Hz AC-3e), 22 kW (at 415V AC 50 Hz AC-3e), 22 kW (at 440V AC 50 Hz AC-3e), 22 kW (at 500V AC 50 Hz AC-3e), 30 kW (at 660 to 690V AC 50 Hz AC-3e)
Rated Voltage690V AC
Working HeightUp to 9842.52 ft
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Electrical Durability2 Mcycles (35 A, AC-3, Less than 440 V), 0.7 Mcycles (60 A, AC-1, Less than 440 V), 2 Mcycles (35 A, AC-3e, Less than 440 V)
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Rated Short-Time Withstand Current72 A (at 40°C for 10 min Power Circuit), 165 A (at 40°C for 1 min Power Circuit), 320 A (at 40°C for 10 s Power Circuit), 720 A (at 40°C for 1 s Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Max. Temperature850°C
Switching Voltage17 V (Signalling Circuit)
Switching Current5 mA (Signalling Circuit)
Watts Loss1.2W
Mounts OnPlate, Rail
Non-Overlap Time1.5 ms
Includes Protective CoverYes
Horsepower @ Three Phase - 240V AC10 hp
Electrical Operating Durability2,000,000, 700,000
Horsepower @ Three Phase - 600V AC30 hp
Minimum Operating Temperature-40 Degrees F
Full Load Current - Inductive40 A
Resistance PropertiesFire Resistant, Insulation Resistant
Reversing CapabilityNon-Reversing
Frequency50/60 Hz
Maximum Voltage Rating690V AC
Horsepower @ Three Phase - 480V AC30 hp
Coil Voltage100-250V AC/DC
Overall Width2.17 in
Full Load Current - Resistive60 A
Number of Normally Open Main Contacts3
PhaseThree
Terminal Connection TypeScrew Clamp Terminals
Maximum Operating Temperature140 Degrees F
Includes Auxiliary ContactsYes
Number of Auxillary Contacts2
Overall Height4.8 in
Mounting StyleDIN Rail, Plate
Horsepower @ Three Phase - 208V AC10 hp
Mechanical Operating Durability6,000,000
Horsepower @ Single Phase - 240V AC5 hp
Contactor StyleIEC
NEMA Enclosure RatingNo Enclosure
NEMA Enclosure MaterialNot Applicable
Horsepower @ Single Phase - 120V AC3 hp
Embedded Surge SuppressorNo
Overall Depth4.72 in
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#100 to 250 V AC/DC
#40 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LC1D40AKUE
#SCHNEIDER ELECTRIC
#GRG6542273
#mfr:LC1D40AKUE
#part number:LC1D40AKUE
#pn:LC1D40AKUE
#part code:LC1D40AKUE
#item number:LC1D40AKUE
#product code:LC1D40AKUE
#manufacturer number:LC1D40AKUE
#manufacturers part number:LC1D40AKUE
#mfn:LC1D40AKUE

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!