Discount -3%

IEC Mini Magnetic Contactor, 3 Poles, 24 V DC, 9 A, Reversing: No, SCHNEIDER, Mfr# LP1K0910BD

$93,45
-3% / ea
with subscription
Free shipping will be applied on orders over $50

Miniature IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 2.28 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC

9999 in stock

Must order in multiples of 1
Subtotal:
$93.45
Final shipping and tax calculated in checkout
Subtotal: $90.65 with subscription
Brand Name: SCHNEIDER
Mfr #: LP1K0910BD
Availability: Ships in 1 days
SKU: GRG2600132 Category:
Full Load Amps-Inductive9 A
ItemMiniature IEC Magnetic Contactor
ActionNon-Reversing
Full Load Amps-Resistive20 A
Number of Poles3
Coil Volts24 V DC
ReversingNo
HP @ 1 Phase - 230V1-1/2
HP @ 1 Phase - 120V1/2 hp
Height1.77 in
HP @ 1 Phase - 240V1 1/2 hp
HP @ 3 Phase - 208V2 hp
Width1.77 in
HP @ 3 Phase - 240V3 hp
HP @ 3 Phase - 575V5 hp
Depth2.24 in
Enclosure NEMA RatingNo Enclosure
HP @ 3 Phase - 480V5 hp
Aux. Contact Configuration1NO
Hz50/60
Auxiliary Contact Form1NO
StandardsCSA, UKCA, UL Listed
Frame / Series / Class / CodeTeSys
SeriesTeSys K
NEMA SizeNot Applicable
Rated Insulation Volts600/690V
Fuse Amps25 A (Power Circuit), 10 A (Signalling Circuit)
Switching Voltage17 V (Signalling Circuit)
Switching Current5 mA (Signalling Circuit)
Mechanical Durability10 Mcycles
Net Weight0.225 kg
Electrical Durability1.3 Mcycles 9 A AC-3 Less than or Equal to 440 V, 1.3 Mcycles 9 A AC-3e Less than or Equal to 440 V, 0.16 Mcycles 20 A AC-1 Less than or Equal to 690 V, 0.02 Mcycles 54 A AC-4 Less than or Equal to 440 V
Control Circuit Voltage LimitsOperational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.1 to 0.75 Uc (at 50°C)
Environmental AttributesMercury Free, Toxic Heavy Metal Free
Thermal Amperage20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Rated Voltage690V AC
Rated Making Capacity110 A
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Tightening Torque0.8 to 1.3 Nm
Impedance3 mOhm
Rated Breaking Capacity110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V
Working Height6561.68 ft
Mounts OnPlate, Rail
ApplicationMotor Control, Resistive Load
Operating Speed3600 cycles per hr
Fire RatingUL 94 V1, NF F 16-101, NF F 16-102
Overvoltage CategoryCAT III
Operating Time30 to 40 ms (Coil Energisation and NO Closing), 10 ms (Coil De-Energisation and NO Opening)
Impulse Withstand Voltage8 kV
Overall Depth2.24 in
Number of Auxillary Contacts1
NEMA Enclosure RatingNo Enclosure
Frequency50/60 Hz
Number of Normally Open Main Contacts3
Full Load Current - Inductive9 A
Maximum Voltage Rating690V AC
Maximum Operating Temperature122 Degrees F
Embedded Surge SuppressorNo
Horsepower @ Three Phase - 600V AC5 hp
Overall Width1.77 in
Horsepower @ Three Phase - 240V AC3 hp
Includes Auxiliary ContactsYes
Horsepower @ Single Phase - 240V AC1 1/2 hp
Overall Height2.28 in
Full Load Current - Resistive20 A
Terminal Connection TypeScrew Clamp Terminals
NEMA Enclosure MaterialNot Applicable
Horsepower @ Three Phase - 480V AC5 hp
Mechanical Operating Durability10,000,000
Minimum Operating Temperature-13 Degrees F
Mounting StyleDIN Rail, Plate
Coil Voltage24V DC
Resistance PropertiesInsulation Resistant
Contactor StyleIEC
Horsepower @ Three Phase - 208V AC2 hp
Horsepower @ Single Phase - 120V AC1/2 hp
Reversing CapabilityNon-Reversing
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz, Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Mounting SupportRail, Plate
Rated Short Time Withstand Current90 A 122°F (50°C) - 1 s for power circuit, 85 A 122°F (50°C) - 5 s for power circuit, 80 A 122°F (50°C) - 10 s for power circuit, 60 A 122°F (50°C) - 30 s for power circuit, 45 A 122°F (50°C) - 1 min for power circuit, 40 A 122°F (50°C) - 3 min for power circuit, 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
Maximum Operating Rate3600 cyc/h
Flame RetardanceV1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
Poles Description3P
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Auxiliary Contact Composition1 NO
Control Circuit TypeDC standard
Ambient Air Temperature For Operation-13 to 122°F (-25 to 50°C)
Minimum Switching Current5 mA for signalling circuit
Contactor ApplicationMotor control, Resistive load
Associated Fuse Rating25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
Operating Altitude6561.68 ft (2000 m) without derating
Hold-In Power Consumption in W3 W 68°F (20°C)
IRMS Rated Making Capacity110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
Product CertificationsCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Inrush Power in W3 W 68°F (20°C))
Utilisation CategoryAC-3, AC-3e, AC-1, AC-4
Ambient Air Temperature For Storage-58 to 176°F (-50 to 80°C)
Motor Power KW2.2 kW 220 to 230 V AC 50/60 Hz AC-3, 4 kW 380 to 415 V AC 50/60 Hz AC-3, 4 kW 440/690 V AC 50/60 Hz AC-3, 2.2 kW 220 to 230 V AC 50/60 Hz AC-3e, 4 kW 380 to 415 V AC 50/60 Hz AC-3e, 4 kW 440/690 V AC 50/60 Hz AC-3e, 2.2 kW 220 to 230 V AC 50/60 Hz AC-4, 4 kW 380 to 415 V AC 50/60 Hz AC-4, 4 kW 440/690 V AC 50/60 Hz AC-4
Power Pole Contact Composition3 NO
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Connections - Terminalsscrew clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end, Power circuit screw clamp terminals 2 0.00 in? (1.5 mm?)flexible with cable end
Rated Operational Current9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Rated Insulation VoltagePower circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14
Auxiliary Contacts TypeInstantaneous 1 NO
Conventional Free Air Thermal Current20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit
IP Degree Of ProtectionIP2X
Heat Dissipation1.3 W
Product Or Component TypeContactor
Minimum Switching Voltage17 V for signalling circuit
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Mini Magnetic Contactor
#3 Poles
#24 V DC
#9 A
#Reversing: No
#SCHNEIDER
#Mfr LP1K0910BD
#SCHNEIDER
#GRG2600132
#mfr:LP1K0910BD
#part number:LP1K0910BD
#pn:LP1K0910BD
#part code:LP1K0910BD
#item number:LP1K0910BD
#product code:LP1K0910BD
#manufacturer number:LP1K0910BD
#manufacturers part number:LP1K0910BD
#mfn:LP1K0910BD

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!