Discount -0%

IEC Magnetic Contactor, 3 Poles, 110 V AC, 12 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2K1210F7

$200,99
-$0.21000000000001 / ea
with subscription
Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 110V AC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC, Maximum Voltage Rating 690V AC

9999 in stock

Must order in multiples of 1
Subtotal:
$200.99
Final shipping and tax calculated in checkout
Subtotal: $200.78 with subscription
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC2K1210F7
Availability: Ships in 1 days
SKU: GRG0478357 Category:
ItemIEC Magnetic Contactor
Full Load Amps-Inductive12 A
ActionReversing
Full Load Amps-Resistive20 A
Number of Poles3
Coil Volts110 V AC
ReversingYes
Height2.28 in
Width3.54 in
Depth2.24 in
Enclosure NEMA RatingNo Enclosure
Aux. Contact ConfigurationNone
Hz50/60
NEMA SizeNot Applicable
SeriesTeSys K
StandardsBS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660
Frame / Series / Class / CodeTeSys
Auxiliary Contact Form1NO
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Rated Insulation Volts600/690V
Mounts OnPlate, Rail
Signalling Circuit FrequencyLess Than 400 Hz
FeaturesPreassembled with Reversing Power Busbar
IP RatingIP20
Operating Time10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
Impulse Withstand Voltage8 kV
Fire RatingUL 94 V1, NF F 16-101, NF F 16-102
Rated Making Capacity144 A @ 690V (AC Power Circuit), 110 A (AC Signalling Circuit)
Impedance3 mOhm
Rated Voltage690V AC
Operating Speed3600 cycles per hr
Hold VA4.5 VA
Electrical ConnectionScrew Clamp Terminals
Rated Short-Time Withstand Current115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit)
Rated Breaking Capacity110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V
Environmental AttributesMercury Free, Toxic Heavy Metal Free
Electrical Durability0.3 Mcycles (20 A, AC-1, Less than 440 V), 1.3 Mcycles (12 A, AC-3, Less than 440 V)
Fuse Amps25 A (Power Circuit), 10 A (Signalling Circuit)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Working Height6561.68 ft
Control Circuit Voltage LimitsOperational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Overvoltage CategoryCAT III
Switching Voltage17 V (Signalling Circuit)
Shock Resistance10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
ApplicationMotor Control, Resistive Load
Watts Loss1.3W
Thermal Amperage20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Max. Operating Watts4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz), 3 kW (at 220 to 230V AC 50/60 Hz), 5.5 kW (at 380 to 415VAC 50/60 Hz), 5.5 kW (at 440V AC 50/60 Hz)
Tightening Torque0.8 to 1.3 Nm
Switching Current5 mA (Signalling Circuit)
Net Weight0.39 kg
Inrush VA30 VA
Mechanical Durability5 Mcycles
Full Load Current - Inductive12 A
Resistance PropertiesInsulation Resistant
Number of Normally Open Main Contacts3
Minimum Operating Temperature-13 Degrees F
Reversing CapabilityReversing
Electrical Operating Durability1,300,000, 300,000
Contactor StyleIEC
Embedded Surge SuppressorNo
NEMA Enclosure MaterialNot Applicable
Frequency50/60 Hz
Coil Voltage110V AC
Maximum Operating Temperature122 Degrees F
Overall Depth2.24 in
Number of Auxillary Contacts1
Mounting StyleDIN Rail, Plate
Maximum Voltage Rating690V AC
Full Load Current - Resistive20 A
Overall Width3.54 in
Includes Auxiliary ContactsYes
Terminal Connection TypeScrew Clamp Terminals
NEMA Enclosure RatingNo Enclosure
Mechanical Operating Durability5,000,000
Overall Height2.28 in
Poles Description3P
Mounting SupportRail, Plate
Utilisation CategoryAC-3, AC-3e, AC-4, AC-1
Motor Power KW3 kW 220 to 230 V AC 50/60 Hz, 5.5 kW 380 to 415 V AC 50/60 Hz, 5.5 kW 440 V AC 50/60 Hz, 4 kW 690 V AC 50/60 Hz
Control Circuit Voltage110 V AC 50/60 Hz
Connections - Terminalsscrew clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end
Product Or Component TypeReversing contactor
Operating Altitude6561.68 ft (2000 m) without derating
Rated Operational Current12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Ambient Air Temperature For Storage-58 to 176°F (-50 to 80°C)
Inrush Power in VA30 VA (at 68°F (20°C))
Non Overlap Distance0.02 in (0.5 mm)
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Interlocking TypeMechanical
Maximum Operating Rate3600 cyc/h
Power Pole Contact Composition3 NO
Device ApplicationControl
Rated Insulation VoltagePower circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14
Minimum Switching Voltage17 V for signalling circuit
Protective TreatmentTC IEC 60068, TC DIN 50016
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Flame RetardanceV1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
Control Circuit TypeAC 50/60 Hz
Rated Short Time Withstand Current115 A 122°F (50°C) - 1 s for power circuit, 105 A 122°F (50°C) - 5 s for power circuit, 100 A 122°F (50°C) - 10 s for power circuit, 75 A 122°F (50°C) - 30 s for power circuit, 55 A 122°F (50°C) - 1 min for power circuit, 50 A 122°F (50°C) - 3 min for power circuit, 25 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
Auxiliary Contacts TypeInstantaneous 1 NO
IRMS Rated Making Capacity144 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
Rated Operational VoltagePower circuit 690 V AC 50/60 Hz, Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
Contactor ApplicationResistive load, Motor control
Hold-In Power Consumption in VA4.5 VA (at 68°F (20°C))
Auxiliary Contact Composition1 NO
Associated Fuse Rating25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
Conventional Free Air Thermal Current20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit
IP Degree Of ProtectionIP20 VDE 0106
Heat Dissipation1.3 W
Product CertificationsCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Ambient Air Temperature For Operation-13 to 122°F (-25 to 50°C)
Mechanical RobustnessShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Minimum Switching Current5 mA for signalling circuit
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#110 V AC
#12 A
#Reversing: Yes
#SCHNEIDER ELECTRIC
#Mfr LC2K1210F7
#SCHNEIDER ELECTRIC
#GRG0478357
#mfr:LC2K1210F7
#part number:LC2K1210F7
#pn:LC2K1210F7
#part code:LC2K1210F7
#item number:LC2K1210F7
#product code:LC2K1210F7
#manufacturer number:LC2K1210F7
#manufacturers part number:LC2K1210F7
#mfn:LC2K1210F7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!