Item | IEC Magnetic Contactor |
Full Load Amps-Inductive | 12 A |
Action | Reversing |
Full Load Amps-Resistive | 20 A |
Number of Poles | 3 |
Coil Volts | 110 V AC |
Reversing | Yes |
Height | 2.28 in |
Width | 3.54 in |
Depth | 2.24 in |
Enclosure NEMA Rating | No Enclosure |
Aux. Contact Configuration | None |
Hz | 50/60 |
NEMA Size | Not Applicable |
Series | TeSys K |
Standards | BS 5424, CSA, IEC 60947, NF C 63-110, UKCA, UL Listed, VDE 0660 |
Frame / Series / Class / Code | TeSys |
Auxiliary Contact Form | 1NO |
Vibration Resistance | 4 G (Contactor Closed), 2 G (Contactor Open) |
Rated Insulation Volts | 600/690V |
Mounts On | Plate, Rail |
Signalling Circuit Frequency | Less Than 400 Hz |
Features | Preassembled with Reversing Power Busbar |
IP Rating | IP20 |
Operating Time | 10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening) |
Impulse Withstand Voltage | 8 kV |
Fire Rating | UL 94 V1, NF F 16-101, NF F 16-102 |
Rated Making Capacity | 144 A @ 690V (AC Power Circuit), 110 A (AC Signalling Circuit) |
Impedance | 3 mOhm |
Rated Voltage | 690V AC |
Operating Speed | 3600 cycles per hr |
Hold VA | 4.5 VA |
Electrical Connection | Screw Clamp Terminals |
Rated Short-Time Withstand Current | 115 A (at 50°C for 1 s Power Circuit), 105 A (at 50°C for 5 s Power Circuit), 100 A (at 50°C for 10 s Power Circuit), 75 A (at 50°C for 30 s Power Circuit), 55 A (at 50°C for 1 min Power Circuit), 50 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 25 A (at 50°C for 15 min Power Circuit) |
Rated Breaking Capacity | 110 A @ 440V, 80 A @ 500V, 70 A @ 660 to 690V |
Environmental Attributes | Mercury Free, Toxic Heavy Metal Free |
Electrical Durability | 0.3 Mcycles (20 A, AC-1, Less than 440 V), 1.3 Mcycles (12 A, AC-3, Less than 440 V) |
Fuse Amps | 25 A (Power Circuit), 10 A (Signalling Circuit) |
Insulation Resistance Range | Greater Than 10 MOhms (Signalling Circuit) |
Working Height | 6561.68 ft |
Control Circuit Voltage Limits | Operational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C) |
Overvoltage Category | CAT III |
Switching Voltage | 17 V (Signalling Circuit) |
Shock Resistance | 10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open) |
Application | Motor Control, Resistive Load |
Watts Loss | 1.3W |
Thermal Amperage | 20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit) |
Max. Operating Watts | 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz), 3 kW (at 220 to 230V AC 50/60 Hz), 5.5 kW (at 380 to 415VAC 50/60 Hz), 5.5 kW (at 440V AC 50/60 Hz) |
Tightening Torque | 0.8 to 1.3 Nm |
Switching Current | 5 mA (Signalling Circuit) |
Net Weight | 0.39 kg |
Inrush VA | 30 VA |
Mechanical Durability | 5 Mcycles |
Full Load Current - Inductive | 12 A |
Resistance Properties | Insulation Resistant |
Number of Normally Open Main Contacts | 3 |
Minimum Operating Temperature | -13 Degrees F |
Reversing Capability | Reversing |
Electrical Operating Durability | 1,300,000, 300,000 |
Contactor Style | IEC |
Embedded Surge Suppressor | No |
NEMA Enclosure Material | Not Applicable |
Frequency | 50/60 Hz |
Coil Voltage | 110V AC |
Maximum Operating Temperature | 122 Degrees F |
Overall Depth | 2.24 in |
Number of Auxillary Contacts | 1 |
Mounting Style | DIN Rail, Plate |
Maximum Voltage Rating | 690V AC |
Full Load Current - Resistive | 20 A |
Overall Width | 3.54 in |
Includes Auxiliary Contacts | Yes |
Terminal Connection Type | Screw Clamp Terminals |
NEMA Enclosure Rating | No Enclosure |
Mechanical Operating Durability | 5,000,000 |
Overall Height | 2.28 in |
Poles Description | 3P |
Mounting Support | Rail, Plate |
Utilisation Category | AC-3, AC-3e, AC-4, AC-1 |
Motor Power KW | 3 kW 220 to 230 V AC 50/60 Hz, 5.5 kW 380 to 415 V AC 50/60 Hz, 5.5 kW 440 V AC 50/60 Hz, 4 kW 690 V AC 50/60 Hz |
Control Circuit Voltage | 110 V AC 50/60 Hz |
Connections - Terminals | screw clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end |
Product Or Component Type | Reversing contactor |
Operating Altitude | 6561.68 ft (2000 m) without derating |
Rated Operational Current | 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 12 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit |
Ambient Air Temperature For Storage | -58 to 176°F (-50 to 80°C) |
Inrush Power in VA | 30 VA (at 68°F (20°C)) |
Non Overlap Distance | 0.02 in (0.5 mm) |
Insulation Resistance | Greater than 10 MOhm for signalling circuit |
Average Impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
Interlocking Type | Mechanical |
Maximum Operating Rate | 3600 cyc/h |
Power Pole Contact Composition | 3 NO |
Device Application | Control |
Rated Insulation Voltage | Power circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14 |
Minimum Switching Voltage | 17 V for signalling circuit |
Protective Treatment | TC IEC 60068, TC DIN 50016 |
Safety Reliability Level | B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 |
Flame Retardance | V1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102 |
Control Circuit Type | AC 50/60 Hz |
Rated Short Time Withstand Current | 115 A 122°F (50°C) - 1 s for power circuit, 105 A 122°F (50°C) - 5 s for power circuit, 100 A 122°F (50°C) - 10 s for power circuit, 75 A 122°F (50°C) - 30 s for power circuit, 55 A 122°F (50°C) - 1 min for power circuit, 50 A 122°F (50°C) - 3 min for power circuit, 25 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit |
Auxiliary Contacts Type | Instantaneous 1 NO |
IRMS Rated Making Capacity | 144 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947 |
Rated Operational Voltage | Power circuit 690 V AC 50/60 Hz, Signalling circuit Less than or Equal to 690 V AC 50/60 Hz |
Contactor Application | Resistive load, Motor control |
Hold-In Power Consumption in VA | 4.5 VA (at 68°F (20°C)) |
Auxiliary Contact Composition | 1 NO |
Associated Fuse Rating | 25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660 |
Conventional Free Air Thermal Current | 20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit |
IP Degree Of Protection | IP20 VDE 0106 |
Heat Dissipation | 1.3 W |
Product Certifications | CB Scheme, CCC, UL, CSA, EAC, CE, UKCA |
Ambient Air Temperature For Operation | -13 to 122°F (-25 to 50°C) |
Mechanical Robustness | Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6 |
Minimum Switching Current | 5 mA for signalling circuit |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
IEC Magnetic Contactor, 3 Poles, 110 V AC, 12 A, Reversing: Yes, SCHNEIDER ELECTRIC, Mfr# LC2K1210F7
$200,99
-$0.21000000000001 / ea
with subscription
Free shipping will be applied on orders over $50
IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 110V AC, Number of Poles 3, Full Load Current - Inductive 12 A, Full Load Current - Resistive 20 A, Reversing Capability Reversing, Overall Height 2.28 in, Overall Width 3.54 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC, Maximum Voltage Rating 690V AC
9999 in stock
Must order in multiples of 1
Subtotal:
$200.99
You must be logged in to post a review.
Reviews
There are no reviews yet.