IEC Magnetic Contactor, 3 Poles, 110 V AC, 9 A, SCHNEIDER ELECTRIC, Mfr# LC2K0910F7

$199,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor

Out of stock

Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC2K0910F7
Availability: Ships in 5 days
SKU: GRG0568797 Category:

Analogues

Full Load Amps-Inductive9 A
ItemIEC Magnetic Contactor
ActionReversing
Full Load Amps-Resistive20 A
Number of Poles3
Coil Volts110 V AC
Height58 mm
Width90 mm
Depth57 mm
Aux. Contact Configuration1NO
SeriesLC2K
StandardsEN/IEC 60947-4-1, GB/T 14048.4, UL 60947-4-1, CSA C22.2 No 60947-4-1, JIS C8201-4-1, CB Scheme, CCC, UL, CSA, EAC, CE, UKCA, TC IEC 60068, TC DIN 50016
Control Circuit Voltage LimitsOperational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.2 to 0.75 Uc (at 50°C)
Net Weight0.39 kg
Electrical Durability0.18 Mcycles (20 A, AC-1, Less than 440 V), 1.3 Mcycles (9 A, AC-3, Less than 440 V), 1.3 Mcycles (9 A, AC-3e, Less than 440 V)
Switching Current5 mA (Signalling Circuit)
Impulse Withstand Voltage8 kV
Rated Short-Time Withstand Current90 A (at 50°C for 1 s Power Circuit), 85 A (at 50°C for 5 s Power Circuit), 80 A (at 50°C for 10 s Power Circuit), 60 A (at 50°C for 30 s Power Circuit), 45 A (at 50°C for 1 min Power Circuit), 40 A (at 50°C for 3 min Power Circuit), 80 A (For 1 s Signalling Circuit), 90 A (For 500 ms Signalling Circuit), 110 A (For 100 ms Signalling Circuit), 20 A (at 50°C for 15 min Power Circuit)
Working Height6561.68 ft
Fuse Amps25 A (Power Circuit), 10 A (Signalling Circuit)
ApplicationMotor Control, Resistive Load
Fire RatingUL 94 V1, NF F 16-101, NF F 16-102
Thermal Amperage20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Environmental AttributesMercury Free, Toxic Heavy Metal Free
Impedance3 mOhm
Watts Loss1.3W
Hold VA4.5 VA
Rated Making Capacity110 A
Rated Insulation Volts600/690V
FeaturesPreassembled with Reversing Power Busbar
Max. Operating Watts2.2 kW (at 220 to 230V AC 50/60 Hz), 4 kW (at 380 to 415VAC 50/60 Hz), 4 kW (at 440V AC 50/60 Hz), 4 kW (at 480V AC 50/60 Hz), 4 kW (at 500 to 600V AC 50/60 Hz), 4 kW (at 660 to 690V AC 50/60 Hz)
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Operating Speed3600 cycles per hr
Switching Voltage17 V (Signalling Circuit)
Operating Time10 to 20 ms (Coil Energisation and NO Closing), 10 to 20 ms (Coil De-Energisation and NO Opening)
Shock Resistance10 G for 11 ms (on X axis with Contactor Closed), 15 G for 11 ms (on Y and Z axis with Contactor Closed), 6 G for 11 ms (on X axis with Contactor Open), 10 G for 11 ms (on Y and Z axis with Contactor Open)
Mechanical Durability5 Mcycles
Inrush VA30 VA
Mounts OnPlate, Rail
Signalling Circuit FrequencyLess Than 400 Hz
Tightening Torque0.8 to 1.3 Nm
Rated Breaking Capacity110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V
Overvoltage CategoryCAT III
Rated Voltage690V AC
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Electrical ConnectionScrew Clamp Terminals
IP RatingIP20
Mechanical RobustnessShocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27, Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27, Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6, Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6
Non Overlap Distance0.02 in (0.5 mm)
Control Circuit TypeAC 50/60 Hz
Product NameTeSys K
Associated Fuse Rating25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
Protective TreatmentTC IEC 60068, TC DIN 50016
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Hold-In Power Consumption in VA4.5 VA (at 68°F (20°C))
Utilisation CategoryAC-3, AC-3e, AC-4, AC-1
Product Or Component TypeReversing contactor
Contactor ApplicationResistive load, Motor control
Auxiliary Contacts TypeInstantaneous 1 NO
Poles Description3P
Conventional Free Air Thermal Current20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit
Interlocking TypeMechanical
Power Pole Contact Composition3 NO
Ambient Air Temperature For Operation-13 to 122°F (-25 to 50°C)
Connections - Terminalsscrew clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end
Rated Short Time Withstand Current90 A 122°F (50°C) - 1 s for power circuit, 85 A 122°F (50°C) - 5 s for power circuit, 80 A 122°F (50°C) - 10 s for power circuit, 60 A 122°F (50°C) - 30 s for power circuit, 45 A 122°F (50°C) - 1 min for power circuit, 40 A 122°F (50°C) - 3 min for power circuit, 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Minimum Switching Current5 mA for signalling circuit
IP Degree Of ProtectionIP20 VDE 0106
Minimum Switching Voltage17 V for signalling circuit
IRMS Rated Making Capacity110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
Rated Operational VoltagePower circuit 690 V AC 50/60 Hz, Signalling circuit Less than or Equal to 690 V AC 50/60 Hz
Device ApplicationControl
Operating Altitude6561.68 ft (2000 m) without derating
Mounting SupportRail, Plate
Rated Insulation VoltagePower circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14
Flame RetardanceV1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Product CertificationsCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Ambient Air Temperature For Storage-58 to 176°F (-50 to 80°C)
Maximum Operating Rate3600 cyc/h
Motor Power KW2.2 kW 220 to 230 V AC 50/60 Hz, 4 kW 380 to 415 V AC 50/60 Hz, 4 kW 440/690 V AC 50/60 Hz
Inrush Power in VA30 VA (at 68°F (20°C))
Rated Operational Current9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Heat Dissipation1.3 W
Control Circuit Voltage110 V AC 50/60 Hz
Auxiliary Contact Composition1 NO
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#110 V AC
#9 A
#SCHNEIDER ELECTRIC
#Mfr LC2K0910F7
#SCHNEIDER ELECTRIC
#GRG0568797
#mfr:LC2K0910F7
#part number:LC2K0910F7
#pn:LC2K0910F7
#part code:LC2K0910F7
#item number:LC2K0910F7
#product code:LC2K0910F7
#manufacturer number:LC2K0910F7
#manufacturers part number:LC2K0910F7
#mfn:LC2K0910F7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!