Item - Relay | Phase Monitor Relay |
Coil Volts | 250VAC/DC |
AC Contact Rating - Relay | 5A @ 250V |
DC Contact Rating - Relay | 7A @ 30V |
Contact Form - Relay | SPDT |
Mounting - Relay | Plug In |
Item | Relay |
Phase Unbalance | No |
Under Voltage | No |
Phase Loss Sensitivity | No |
Over Voltage | No |
Body Height - Relay | 2.84 in |
Phase Reversal | No |
Input or Control Voltage | 183 to 528V AC |
Body Width - Relay | 0.69 in |
Base Type - Plug In Relay | Octal |
Body Depth - Relay | 3.54 in |
Restart | Auto |
Standards | C-Tick, CSA Certified, EN/IEC 60255-1, EN/IEC 61000-6-4, EU RoHS, GL, GOST, Reach Regulation, UL Listed |
Response Time | < 200 ms (in the event of a fault) |
Contact Form | SPDT |
Mounting Style | DIN Rail |
Current Rating | 5 A |
Flat Pin Width | Not Applicable |
Electrical Operating Durability | 100,000 |
Maximum Operating Temperature | 122 Degrees F |
Minimum Operating Temperature | -4 Degrees F |
Weight | 4.64 oz |
Body Height | 3.54 in |
Body Width | 0.69 in |
Number of Pins | 6 |
Overvoltage | No |
Maximum Switching Current | 5 A |
Electrical Connection Type | Screw |
Overall Depth | 2.84 in |
Contact Rating (AC) | 5 A @ 250V |
Maximum Switching Voltage | 250V AC/DC |
Frequency | 50/60 Hz |
Socket Code Configurator | DIN-Rail / Octal / 6 |
IP Rating | IP30 |
Base Shape | Octal |
Minimum Switching Current | 10 mA |
Housing Material | Plastic |
Monitored Parameters | Phase Failure, Phase Sequence, Undervoltage |
Contact Rating (DC) | 7 A @ 30V |
Power Consumption | 1,250 VA |
Maximum Switching Capacity | 1,250 VA |
Restart Time Delay | 1.5 sec |
Relay Mounting Style | DIN-Rail |
Mechanical Operating Durability | 30,000,000 |
Input Voltage | 183 to 528V AC |
Body Depth | 2.84 in |
Output Contacts | 1 C/O |
Utilisation Category | AC-12 IEC 60947-5-1 || AC-13 IEC 60947-5-1 || AC-14 IEC 60947-5-1 || AC-15 IEC 60947-5-1 || DC-12 IEC 60947-5-1 || DC-13 IEC 60947-5-1 |
Nominal Output Current | 5A |
Product Or Component Type | 3-phase control relay |
[Ui] Rated Insulation Voltage | 400 V IEC 60664-1 |
Power Consumption In Va | 0-22 VA 400 V AC 50 Hz |
Repeat Accuracy | 0.5 % input and measurement circuit || 3 % time delay |
Connections - Terminals | screw terminals, 1 x 0.5...1 x 4 mm? AWG 20...AWG 11) solid without cable end || screw terminals, 2 x 0.5...2 x 2.5 mm? AWG 20...AWG 14) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm? AWG 24...AWG 12) flexible with cable end || screw terminals, 2 x 0.2...2 x 1.5 mm? AWG 24...AWG 16) flexible with cable end |
Control Circuit Frequency | 50...60 Hz +/- 10 % |
Width | 17.5 mm |
Pollution Degree | 3 IEC 60664-1 |
Contacts Type And Composition | 1 C/O |
Operating Position | any position without derating |
Supply Frequency | 50/60 Hz +/- 10 % |
Shock Resistance | 15 gn 11 ms IEC 60255-21-1 |
Reset Time | 1500 ms time delay |
Control Circuit Voltage Limits | 12 % + 10 % Un |
Mechanical Durability | 30000000 cycles |
Measurement Error | < 0.05 %/°C with temperature variation || < 1 % over the whole range with voltage variation |
Dielectric Test Voltage | 2 kV AC 50 Hz, 1 min IEC 60255-5 || 2 kV AC 50 Hz, 1 min IEC 60664-1 |
Electrical Durability | 100000 cycles |
Tightening Torque | 0.6-1 N.m IEC 60947-1 |
Threshold Adjustment Voltage | -2...-12 % in the range 208 V AC || -2...-17 % in the range 220 V AC || 2...20 % of Un selected || +2...+17 % in the range 480 V AC |
Mounting Support | 35 mm symmetrical DIN rail conforming to EN/IEC 60715 |
Relative Humidity | 95-95 % 55-55°C IEC 60068-2-30 |
Relay Name | RM17TU |
Overvoltage Category | III IEC 60664-1 |
Phase Failure Sensitivity | 0.7 Un |
Hysteresis | 2-2 % |
[Uc] Control Circuit Voltage | 208...480 V |
Time Delay Type | adjustable 0.1...10 s, +/- 10 % of the full scale value |
Non-Dissipating Shock Wave | 4 kV IEC 60255-5 || 4 kV IEC 60664-1 || 4 kV IEC 61000-4-5 |
Product Certifications | GL || GOST || UL || C-tick || CSA |
Operating Rate | <= 360 operations/hour full load |
Supply Voltage Limits | 183-528 V AC |
Insulation Resistance | > 500 MOhm 500 V DC IEC 60255-5 || > 500 MOhm 500 V DC IEC 60664-1 |
Relay Type | multifunction control relay |
Vibration Resistance | 0.35 mm 5-57.6 Hz)IEC 60068-2-6 || 1 gn 57.6-150 Hz)IEC 60255-21-1 |
Ambient Air Temperature For Operation | -20-50°C |
Measurement Range | 208...480 V voltage AC |
Run-Up Delay At Power-Up | 650 ms |
Maximum Measuring Cycle | 150 ms measurement cycle as true rms value |
Ip Degree Of Protection | IP20 IEC 60529 terminals) || IP30 IEC 60529 casing) |
Switching Capacity In Va | 1250 VA |
Adjustment Of Asymmetry Threshold | 5...15 % of Un selected |
Marking | CE |
Local Signalling | for power ON LED (green) || for relay ON LED (yellow) |
Relay Monitored Parameters | undervoltage detection || phase sequence || phase failure detection |
Voltage Range | 208...480 V phase to phase |
Product Specific Application | for 3-phase supply |
Electromagnetic Compatibility | emission standard for industrial environments EN/IEC 61000-6-4 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || immunity for industrial environments EN/IEC 61000-6-2 |
Measurement Voltage Limits | 183-528 V AC |
Ambient Air Temperature For Storage | -40-70°C |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
3 Phase Relay 250V 5Amp Rm17, SCHNEIDER ELECTRIC, Mfr# RM17TU00
$139,99
Free shipping will be applied on orders over $50
Relay, Base Shape Octal, Contact Form SPDT, Contact Rating (AC) 5 A @ 250V, Contact Rating (DC) 7 A @ 30V, Current Rating 5 A, Flat Pin Width Not Applicable, Input Voltage 183 to 528V AC, Monitored Parameters Phase Failure, Phase Sequence, Undervoltage, Number of Pins 6, Restart Auto, Restart Time Delay 1.5 sec, IP Rating IP30, Mounting Style DIN Rail, Body Depth 2.84 in, Body Height 3.54 in, Body Width 0.69 in, Electrical Operating Durability 100,000, Frequency 50/60 Hz
0 in stock
Must order in multiples of 1
Subtotal:
$139.99
You must be logged in to post a review.