Item - Relay | Current Sensing Relay |
AC Contact Rating - Relay | 8 A @ 250 V |
DC Contact Rating - Relay | 0.01 A @ 5V |
Contact Form - Relay | DPDT |
Mounting - Relay | Surface |
Response Time | <= 300 ms |
Contact Form | DPDT |
Item | Phase Control Relay |
Body Height - Relay | 3.54 in |
Body Width - Relay | 0.9 in |
Body Depth - Relay | 3.15 in |
Standards | C-Tick, CSA Certified, EN/IEC 60255-1, EN/IEC 61000-6-4, EU RoHS, GL, GOST, Reach Regulation, UL Listed |
Electrical Connection | Terminal Strip |
Input or Control Voltage | 200 to 240 V AC |
Sensing Amp Range | 0.01 to 8.00 A |
Trip Point | Adjustable 0.01 to 8.00 A |
Core Type - Relay | Solid |
Type of Output | Relay |
Trip Delay | 0.10 to 30 sec |
Minimum Switching Current | 10 mA |
Flat Pin Width | Not Applicable |
Maximum Operating Temperature | 122 Degrees F |
Electrical Connection Type | Screw |
Input Voltage | 380 to 480V AC |
Contact Rating (AC) | 8 A @ 250V |
Current Rating | 8 A |
Mechanical Operating Durability | 30,000,000 |
Electrical Operating Durability | 100,000 |
Weight | 3.2 oz |
Mounting Style | DIN Rail |
Relay Mounting Style | DIN-Rail |
Body Width | 0.89 in |
Body Depth | 3.13 in |
Monitored Parameters | Overvoltage, Phase Failure, Phase Sequence |
Body Height | 3.54 in |
Contact Rating (DC) | 0.01 A @ 5V |
Maximum Switching Current | 8 A |
Restart | Auto |
Housing Material | Plastic |
IP Rating | IP40 |
Overall Depth | 3.13 in |
Maximum Switching Voltage | 250V AC |
Restart Time Delay | 1.5 sec |
Maximum Switching Capacity | 1,250 VA |
Power Consumption | 1,250 VA |
Socket Code Configurator | DIN-Rail / 9 |
Number of Pins | 9 |
Frequency | 50/60 Hz |
Minimum Operating Temperature | -4 Degrees F |
Setting Accuracy Of Time Delay | 0.916666666666667 |
Setting Accuracy Of The Switching Threshold | +/- 10 % of the full scale |
Threshold Adjustment Voltage | 2...20 % of Un selected |
Overvoltage Category | III IEC 60664-1 || III UL 508 |
Ip Degree Of Protection | IP20 IEC 60529 terminals) || IP40 IEC 60529 housing) || IP50 IEC 60529 front panel) |
Width | 22.5 mm |
Run-Up Delay At Power-Up | 650 ms |
Ambient Air Temperature For Operation | -20-50°C 60 Hz || -20-60°C 50 Hz AC/DC |
Repeat Accuracy | +/- 0.5 % input and measurement circuit || +/- 3 % time delay |
Nominal Output Current | 8A |
Measurement Error | < 1 % over the whole range with voltage variation || < 0.05 %/°C with temperature variation |
Time Delay Type | adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt |
Relay Name | RM22TR |
Electrical Durability | 100000 cycles |
Hysteresis | 2-2 % fixed selectable |
Maximum Measuring Cycle | 150 ms measurement cycle as true rms value |
Control Circuit Voltage Limits | 20 % + 20 % Un |
Relay Monitored Parameters | overvoltage and undervoltage detection || phase sequence || phase failure detection |
Tightening Torque | 0.6-1 N.m IEC 60947-1 |
Connections - Terminals | screw terminals, 2 x 0.5...2 x 2.5 mm? AWG 20...AWG 14) solid without cable end || screw terminals, 2 x 0.2...2 x 1.5 mm? AWG 24...AWG 16) flexible with cable end || screw terminals, 1 x 0.5...1 x 3.3 mm? AWG 20...AWG 12) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm? AWG 24...AWG 14) flexible with cable end |
Voltage Range | 380...480 V phase to phase |
Supply Frequency | 50...60 Hz +/- 10 % |
Time Delay Drift | <= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range |
Contacts Material | cadmium free |
Immunity To Microbreaks | 10 ms |
[Us] Rated Supply Voltage | 380...480 V AC |
Relative Humidity | 93-97 % 25-55°C IEC 60068-2-30 |
Pollution Degree | 3 IEC 60664-1 || 3 UL 508 |
Utilisation Category | AC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1 |
Output Contacts | 2 C/O |
Switching Capacity In Va | 2000 VA |
Vibration Resistance | 0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6 |
Voltage Detection Threshold | < 100 V AC |
Relay Type | control relay |
Product Or Component Type | 3-phase control relay |
Ambient Air Temperature For Storage | -40-70°C |
Status Led | LED (Yellow) relay ON || LED (Green) power ON |
Switching Threshold Drift | <= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range |
Mounting Position | any position |
Power Consumption In Va | 15-15 VA 480 V AC 60 Hz |
Mechanical Durability | 10000000 cycles |
Mounting Support | 35 mm DIN rail conforming to EN/IEC 60715 |
Reset Time | 1500 ms at maximum voltage |
Product Certifications | GL || CSA || RCM || CE || EAC || CCC || UL |
Contacts Type And Composition | 2 C/O |
Shock Resistance | 15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27 |
Measurement Range | 380...480 V voltage AC |
Insulation Resistance | > 100 MOhm 500 V DC IEC 60255-27 |
Phase | 3 phase |
Dielectric Test Voltage | 2.5 kV AC 50 Hz, 1 min IEC 60255-27 |
Supply Voltage Limits | 304-576 V AC |
Electromagnetic Compatibility | immunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22 |
Country of Origin (subject to change) | Multiple |
Package Quantity | 1 |
Phase Ctrl Relay, 380-480VAC In 8A, Dpdt, SCHNEIDER ELECTRIC, Mfr# RM22TR33
$140,99
Free shipping will be applied on orders over $50
Phase Control Relay, Contact Form DPDT, Contact Rating (AC) 8 A @ 250V, Contact Rating (DC) 0.01 A @ 5V, Current Rating 8 A, Flat Pin Width Not Applicable, Input Voltage 380 to 480V AC, Monitored Parameters Overvoltage, Phase Failure, Phase Sequence, Number of Pins 9, Restart Auto, Restart Time Delay 1.5 sec, IP Rating IP40, Mounting Style DIN Rail, Body Depth 3.13 in, Body Height 3.54 in, Body Width 0.89 in, Electrical Operating Durability 100,000, Frequency 50/60 Hz, Housing Material Plastic
9999 in stock
Must order in multiples of 1
Subtotal:
$140.99
You must be logged in to post a review.