Monitor Relay, 5 A, 24-240VAC/DC, 12 Pin, SCHNEIDER ELECTRIC, Mfr# RM35JA32MR

$142,99
Free shipping will be applied on orders over $50

Monitor Relay, Contact Form DPDT, Contact Rating (AC) 8 A @ 250V, Contact Rating (DC) 0.01 A @ 5V, Current Rating 5 A, Input Voltage 24 to 240V AC/DC, Monitored Parameters Overcurrent, Undercurrent, Mounting Style Surface, Number of Pins 12, Trip Point Adjustable 0.15 to 15.00 A, Electrical Connection Terminal Strip, Body Depth 2.84 in, Body Height 3.54 in, Body Width 1.38 in

9999 in stock

Must order in multiples of 1
Subtotal:
$142.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: RM35JA32MR
Availability: Ships in 5 days
SKU: GRG5956859 Category:
Item - RelayCurrent Sensing Relay
AC Contact Rating - Relay8 A @ 250 V
DC Contact Rating - Relay0.01 A @ 5V
Contact Form - RelayDPDT
Mounting - RelaySurface
Body Height - Relay3.54 in
Response Time<= 500 ms (on crossing the threshold)
Body Width - Relay1.38 in
Contact FormDPDT
ItemMonitor Relay
StandardsCCC, CE Certified, CSA Certified, EAC, EN/IEC 60255-1, GL, RCM, UL Listed
Overall Height - Relay3.65 in
Body Depth - Relay2.83 in
Trip Delay0.1 to 30 sec
Input or Control Voltage24 to 240 V AC/DC
Electrical ConnectionTerminal Strip
Trip PointAdjustable 0.15 to 15.00 A
Sensing Amp Range0.15 to 15.00 A
Type of OutputRelay
Core Type - RelaySolid
Minimum Operating Temperature-40 Degrees F
Weight0.26 lb
Body Depth2.84 in
Mounting StyleSurface
Maximum Operating Temperature158 Degrees F
Maximum Switching Capacity2,000 VA
Overall Depth2.84 in
Contact Rating (DC)0.01 A @ 5V
Contact Rating (AC)8 A @ 250V
Body Height3.54 in
Body Width1.38 in
Monitored ParametersOvercurrent, Undercurrent
Minimum Switching Current10 mA
Number of Pins12
Power Consumption1 W
Current Rating5 A
IP RatingIP20, IP30, IP50
Maximum Switching Voltage250V AC
Input Voltage24 to 240V AC/DC
Mechanical Operating Durability10,000,000
Insulation Resistance> 100 MOhm 500 V DC IEC 60255-27
Local Signallingfor relay ON LED (yellow) || for power ON LED (green)
Product Or Component Typecurrent control relay
Connections - Terminalsscrew terminals, 2 x 0.5...2 x 2.5 mm? AWG 20...AWG 14) solid without cable end || screw terminals, 2 x 0.2...2 x 1.5 mm? AWG 24...AWG 16) flexible with cable end || screw terminals, 1 x 0.5...1 x 3.3 mm? AWG 20...AWG 12) solid without cable end || screw terminals, 1 x 0.2...1 x 2.5 mm? AWG 24...AWG 14) flexible with cable end
Threshold Setting10...100 %
Relay NameRM35JA
Time Delay Typeadjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
Run-Up Delay At Power-Up0.3 s
Setting Accuracy Of Time Delay0.916666666666667
Pollution Degree3 IEC 60664-1 || 3 UL 508
Internal Input Resistance0.015 Ohm || 0.005 Ohm || 0.05 Ohm
Time Delay Drift<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range
Ip Degree Of ProtectionIP20 IEC 60529 terminals) || IP50 IEC 60529 front panel) || IP30 IEC 60529 housing)
Electromagnetic Compatibilityimmunity for residential, commercial and light-industrial environments EN/IEC 61000-6-1 || immunity for industrial environments EN/IEC 61000-6-2 || emission standard for industrial environments EN/IEC 61000-6-4 || electrostatic discharge 6 kV contact discharge)level 3 IEC 61000-4-2 || electrostatic discharge 8 kV air discharge)level 3 IEC 61000-4-2 || radiated radio-frequency electromagnetic field immunity test 10 V/mlevel 3 IEC 61000-4-3 || electrical fast transient/burst immunity test 4 kV direct)level 4 IEC 61000-4-4 || electrical fast transient/burst immunity test 2 kV capacitive coupling)level 4 IEC 61000-4-4 || surge immunity test 4 kV common mode)level 4 IEC 61000-4-5 || surge immunity test 2 kV differential mode)level 4 IEC 61000-4-5 || conducted and radiated emissionsclass B group 1 CISPR 11 || conducted and radiated emissionsclass B CISPR 22 || emission standard for residential, commercial and light-industrial environments except radiated emission) EN/IEC 61000-6-3
Contacts Type And Composition2 C/O
Maximum Power Consumption In Va3.5 VA
Switching Threshold Drift<= 0.05 % per degree centigrade depending permissible ambient air temperature || <= 1 % within the supply voltage range
Ambient Air Temperature For Storage-40-70°C
Maximum Switching Current8 A AC
Setting Accuracy Of The Switching Threshold+/- 10 % of the full scale
[Us] Rated Supply Voltage24...240 V AC/DC 50/60 Hz +/- 10 %
Insulationbetween supply and measurement
Vibration Resistance0.075 mm 10-58.1 Hz) not in operation IEC 60068-2-6 || 1 gn 10-58.1 Hz) not in operation IEC 60068-2-6 || 0.035 mm 58.1-150 Hz) in operation IEC 60068-2-6 || 0.5 gn 58.1-150 Hz) in operation IEC 60068-2-6
Mechanical Durability10000000 cycles
Shock Resistance15 gn 11 ms) not in operation IEC 60068-2-27 || 5 gn 11 ms) in operation IEC 60068-2-27
Housing Materialself-extinguishing plastic
Repeat Accuracy+/- 0.5 % input and measurement circuit || +/- 2 % time delay
Relay Monitored Parametersovercurrent or undercurrent in window mode || overcurrent or undercurrent detection
Electrical Durability100000 cycles
Nominal Output Current8A
Utilisation CategoryAC-15 IEC 60947-5-1 || DC-13 IEC 60947-5-1 || AC-1 IEC 60947-4-1 || DC-1 IEC 60947-4-1
Resistance Across Terminals0.005 Ohm E3-M terminals || 0.015 Ohm E2-M terminals || 0.05 Ohm E1-M terminals
Measurement Range0.15...1.5 A E1-M terminals || 0.5...5 A E2-M terminals || 1.5...15 A E3-M terminals || 150 mA...15 A current AC/DC 50/60 Hz
Mounting Support35 mm DIN rail conforming to EN/IEC 60715
Tightening Torque0.6-1 N.m IEC 60947-1
Environmental Characteristic3K3 C
Relay Typecurrent control relay
Maximum Power Consumption In W1.5 W DC
Maximum Measuring Cycle100 ms measurement cycle as true rms value
Ambient Air Temperature For Operation-20-50°C 60 Hz || -20-60°C 50 Hz
Switching Capacity In Va2000 VA
Relative Humidity93-97 % 25-55°C IEC 60068-2-30
Reset Time1500 ms at maximum voltage
Control Circuit Voltage Limits15 % + 10 % Un
Dielectric Test Voltage2.5 kV AC 50 Hz, 1 min IEC 60255-27
Product CertificationsCE || GL || CCC || EAC || RCM || UL || CSA
Hysteresis5-50 % adjustable threshold setting || 3-3 % fixed full scale for window mode
Immunity To Microbreaks50 ms
Width35 mm
Output Contacts2 C/O
Overvoltage CategoryIII IEC 60664-1 || III UL 508
Supply Voltage Limits20.4-264 V AC/DC
Measurement Error< 1 % over the whole range with voltage variation || 0.05 %/°C with temperature variation
Contacts Materialcadmium free
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#Monitor Relay
#5 A
#24-240VAC/DC
#12 Pin
#SCHNEIDER ELECTRIC
#Mfr RM35JA32MR
#SCHNEIDER ELECTRIC
#GRG5956859
#mfr:RM35JA32MR
#part number:RM35JA32MR
#pn:RM35JA32MR
#part code:RM35JA32MR
#item number:RM35JA32MR
#product code:RM35JA32MR
#manufacturer number:RM35JA32MR
#manufacturers part number:RM35JA32MR
#mfn:RM35JA32MR

Reviews

There are no reviews yet.

Add a review
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
You have not viewed any product yet!