IEC Magnetic Contactor, 3 Poles, 48 V AC, 9 A, SCHNEIDER ELECTRIC, Mfr# LC1D09E7

$109,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor

9999 in stock

Must order in multiples of 1
Subtotal:
$109.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LC1D09E7
Availability: Ships in 5 days
SKU: GRG0569530 Category:

Analogues

Full Load Amps-Inductive9 A
ItemIEC Magnetic Contactor
Full Load Amps-Resistive25 A
Number of Poles3
Coil Volts48 V AC
HP @ 1 Phase - 240V1 hp
Height77 mm
Width45 mm
HP @ 3 Phase - 208V2 hp
HP @ 3 Phase - 240V2 hp
Depth86 mm
HP @ 3 Phase - 575V7 1/2 hp
HP @ 3 Phase - 480V5 hp
Aux. Contact Configuration1NO/1NC
StandardsCSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508, IEC 60335-1, GOST, GL, LROS, DNV, UL, RINA, CCC, BV, CSA, UKCA, THIEC 60068-2-30
SeriesLC1D
Mounts OnPlate, Rail
Rated Voltage690V AC, 300V DC
Rated Short-Time Withstand Current105 A (at 40°C for 10 s Power Circuit), 210 A (at 40°C for 1 s Power Circuit), 30 A (at 40°C for 10 min Power Circuit), 61 A (at 40°C for 1 min Power Circuit), 100 A (For 1 s Signalling Circuit), 120 A (For 500 ms Signalling Circuit), 140 A (For 100 ms Signalling Circuit)
Operating Time12 to 22 ms (Closing), 4 to 19 ms (Opening)
Fuse Amps10 A (Signalling Circuit), 25 A (Type 1 Power Circuit), 20 A (Type 2 Power Circuit)
Electrical ConnectionScrew Clamp Terminals
Rated Breaking Capacity250 A @ 440V
Signalling Circuit Frequency25 to 400 Hz
ApplicationMotor Control, Resistive Load
Switching Current5 mA (Signalling Circuit)
Includes Protective CoverYes
IP RatingIP20
Switching Voltage17 V (Signalling Circuit)
Fire RatingUL 94 V1
Thermal Amperage25 A (at 60°C Power Circuit), 10 A (at 60°C Signalling Circuit)
Max. Temperature850°C
Hold VA7.5 VA (at 60 Hz 20°C), 7 VA (at 50 Hz 20°C)
Tightening Torque1.7 Nm
Rated Insulation Volts600/690V
Impulse Withstand Voltage6 kV
Impedance2.5 mOhm
Overvoltage CategoryCAT III
Rated Making Capacity250 A @ 440V (Power Circuit), 140 A (AC Signalling Circuit), 250 A (DC Signalling Circuit)
Electrical Durability0.6 Mcycles (25 A, AC-1, Less than 440 V), 2 Mcycles (9 A, AC-3, Less than 440 V), 2 Mcycles (9 A, AC-3e, Less than 440 V)
FeaturesWithout Built-In Suppressor Module
Non-Overlap Time1.5 ms
Watts Loss2 to 3W
Control Circuit Voltage LimitsDrop-Out AC: 0.3 to 0.6 Uc (at -40 to 70°C 50/60 Hz), Operational AC: 0.8 to 1.1 Uc (at -40 to 60°C 50 Hz), 0.85 to 1.1 Uc (at -40 to 60°C 60 Hz), 1 to 1.1 Uc (at 60 to 70°C 50/60 Hz)
Inrush VA70 VA
Shock Resistance15 G for 11 ms (Contactor Closed), 10 G for 11 ms (Contactor Open)
Vibration Resistance4 G (Contactor Closed), 2 G (Contactor Open)
Max. Operating Watts2.2 kW (at 220 to 230V AC 50/60 Hz AC-3), 4 kW (at 380 to 400V AC 50/60 Hz AC-3), 4 kW 415 to (at 440V AC 50/60 Hz AC-3), 5.5 kW (at 500V AC 50/60 Hz AC-3), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3), 2.2 kW (at 400V AC 50/60 Hz AC-4), 2.2 kW (at 220 to 230V AC 50/60 Hz AC-3e), 4 kW (at 380 to 400V AC 50/60 Hz AC-3e), 4 kW 415 to (at 440V AC 50/60 Hz AC-3e), 5.5 kW (at 500V AC 50/60 Hz AC-3e), 5.5 kW (at 660 to 690V AC 50/60 Hz AC-3e)
Net Weight0.32 kg
Mechanical Durability15 Mcycles
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Working HeightUp to 9842.52 ft
Environmental AttributesMercury Free, PVC Free, Toxic Heavy Metal Free, Pollution Degree 3
Operating Speed3600 cycles per hr
IRMS Rated Making Capacity250 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1
Contact CompatibilityM2
Flame RetardanceV1 conforming to UL 94
Auxiliary Contacts TypeMechanically linked 1 NO + 1 NC IEC 60947-5-1, Mirror contact 1 NC IEC 60947-4-1
Minimum Switching Voltage17 V for signalling circuit
Hold-In Power Consumption in VA7.5 VA 60 Hz cos phi 0.3 (at 68°F (20°C)), 7 VA 50 Hz cos phi 0.3 (at 68°F (20°C))
IP Degree Of ProtectionIP20 front face IEC 60529
Control Circuit Voltage48 V AC 50/60 Hz
Mechanical RobustnessVibrations contactor open 2 Gn, 5 to 300 Hz), Vibrations contactor closed 4 Gn, 5 to 300 Hz), Shocks contactor open 10 Gn for 11 ms), Shocks contactor closed 15 Gn for 11 ms)
Maximum Operating Rate3600 cyc/h 140°F (60°C)
Associated Fuse Rating10 A gG for signalling circuit conforming to IEC 60947-5-1, 25 A gG at Less than or Equal to 690 V coordination type 1 for power circuit, 20 A gG at Less than or Equal to 690 V coordination type 2 for power circuit
Conventional Free Air Thermal Current25 A (at 140°F (60°C)) for power circuit, 10 A (at 140°F (60°C)) for signalling circuit
Maximum Horse Power Rating1 hp at 230/240 V AC 50/60 Hz for 1 phase motors, 2 hp at 200/208 V AC 50/60 Hz for 3 phase motors, 2 hp at 230/240 V AC 50/60 Hz for 3 phase motors, 5 hp at 460/480 V AC 50/60 Hz for 3 phase motors, 7.5 hp at 575/600 V AC 50/60 Hz for 3 phase motors, 0.33 hp at 115 V AC 50/60 Hz for 1 phase motors
Pollution Degree3
Operating Altitude0 to 9842.52 ft (0 to 3000 m)
Motor Power KW2.2 kW at 220 to 230 V AC 50/60 Hz (AC-3), 4 kW at 380 to 400 V AC 50/60 Hz (AC-3), 4 kW at 415 to 440 V AC 50/60 Hz (AC-3), 5.5 kW at 500 V AC 50/60 Hz (AC-3), 5.5 kW at 660 to 690 V AC 50/60 Hz (AC-3), 2.2 kW at 400 V AC 50/60 Hz (AC-4), 2.2 kW at 220 to 230 V AC 50/60 Hz (AC-3e), 4 kW at 380 to 400 V AC 50/60 Hz (AC-3e), 4 kW at 415 to 440 V AC 50/60 Hz (AC-3e), 5.5 kW at 500 V AC 50/60 Hz (AC-3e), 5.5 kW at 660 to 690 V AC 50/60 Hz (AC-3e)
Pole Contact Composition3 NO
Protective CoverWith
Average Impedance2.5 mOhm - Ith 25 A 50 Hz for power circuit
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC 25 to 400 Hz, Power circuit Less than or Equal to 300 V DC
Utilisation CategoryAC-3, AC-4, AC-1, AC-3e
Minimum Switching Current5 mA for signalling circuit
Protective TreatmentTHIEC 60068-2-30
Rated Operational Current9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 25 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-1 for power circuit, 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit
Rated Short Time Withstand Current105 A 104°F (40°C) - 10 s for power circuit, 210 A 104°F (40°C) - 1 s for power circuit, 30 A 104°F (40°C) - 10 min for power circuit, 61 A 104°F (40°C) - 1 min for power circuit, 100 A - 1 s for signalling circuit, 120 A - 500 ms for signalling circuit, 140 A - 100 ms for signalling circuit
Fire Resistance1562°F (850°C) IEC 60695-2-1
Heat Dissipation2 to 3 W at 50/60 Hz
Connections - TerminalsPower circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Power circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Power circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible without cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 2 0.00 to 0.00 in? (1 to 2.5 mm?) - cable stiffness: flexible with cable end, Control circuit: screw clamp terminals 1 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end, Control circuit: screw clamp terminals 2 0.00 to 0.01 in? (1 to 4 mm?) - cable stiffness: solid without cable end
Control Circuit TypeAC 50/60 Hz standard
Permissible Ambient Air Temperature Around The Device-40 to 140°F (-40 to 60°C), 140 to 158°F (60 to 70°C) with derating
Rated Impulse Withstand Voltage6 kV IEC 60947
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Climatic WithstandIACS E10 exposure to damp heat, IEC 60947-1 Annex Q category D exposure to damp heat
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Auxiliary Contact Composition1 NO + 1 NC
Rated Insulation VoltagePower circuit 690 V IEC 60947-4-1, Power circuit 600 V CSA, Power circuit 600 V UL, Signalling circuit 690 V IEC 60947-1, Signalling circuit 600 V CSA, Signalling circuit 600 V UL
Product Or Component TypeContactor
Poles Description3P
Power Dissipation Per Pole1.56 W AC-1, 0.2 W AC-3, 0.2 W AC-3e
Inrush Power in VA70 VA 60 Hz cos phi 0.75 (at 68°F (20°C)), 70 VA 50 Hz cos phi 0.75 (at 68°F (20°C))
Contactor ApplicationMotor control, Resistive load
Product CertificationsGOST, GL, LROS (Lloyds register of shipping), DNV, UL, RINA, CCC, BV, CSA, UKCA
Mounting SupportRail, Plate
Country of Origin (subject to change)Indonesia
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#48 V AC
#9 A
#SCHNEIDER ELECTRIC
#Mfr LC1D09E7
#SCHNEIDER ELECTRIC
#GRG0569530
#mfr:LC1D09E7
#part number:LC1D09E7
#pn:LC1D09E7
#part code:LC1D09E7
#item number:LC1D09E7
#product code:LC1D09E7
#manufacturer number:LC1D09E7
#manufacturers part number:LC1D09E7
#mfn:LC1D09E7

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!