Item | Overload Module |
Voltage | 24V AC |
Phase | Single |
Thermal Setting Range (A) | 0.30 to 1.40 |
For Use With | LUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12 |
Trip Class | 10 |
Reset Type - Relay | Manual |
Sensing Method | Electronic |
Features | Earth Fault Protection |
Current Range | 0.35 to 1.40A |
Number of Poles | 3 |
Standards | ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed |
Trip Class - Overload | 10 |
Ip Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1 |
Product Certifications | CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine |
[Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
Thermal Overload Class | class 10 40-60 Hz -25-55°C IEC 60947-6-2 || class 10 40-60 Hz -25-55°C UL 508 |
Load Type | single-phase motor |
Shock Resistance | 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27 |
Height | 66 mm |
Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2 |
Product Compatibility | power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12B || reversing contactor breaker LU2B32B |
Width | 45 mm |
[Uc] Control Circuit Voltage | 24 V AC |
Range | TeSys |
Product Name | TeSys Ultra |
Typical Current Consumption | 140 mA 24 V AC I maximum while closing with LUB12 || 220 mA 24 V AC I maximum while closing with LUB32 || 220 mA 24 V AC I maximum while closing with LUB38 || 70 mA 24 V AC I rms sealed with LUB12 || 90 mA 24 V AC I rms sealed with LUB32 || 90 mA 24 V AC I rms sealed with LUB38 |
Product Specific Application | basic protection and advanced functions, communication |
Immunity To Microbreaks | 3 ms |
Protective Treatment | TH IEC 60068 |
Device Application | motor control || motor protection |
[Ue] Rated Operational Voltage | 690 V AC |
Non-Dissipating Shock Wave | 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2 |
Immunity To Voltage Dips | 70 % / 500 ms IEC 61000-4-11 |
Function Available | manual reset || earth fault protection || protection against phase failure and phase imbalance || protection against overload and short-circuit |
Resistance To Radiated Fields | 10 V/m 3 IEC 61000-4-3 |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Network Frequency | 40 to 60 Hz |
Operating Altitude | 6561.68 ft (2000 m) |
Fire Resistance | 960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12 |
Fixing Mode | plug-in front face) |
Tripping Threshold | 14.2 x Ir +/- 20 % |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
Heat Dissipation | 2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38 |
Product Or Component Type | advanced control unit |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
Ambient Air Temperature For Storage | -40-85°C |
Vibration Resistance | 2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6 |
Thermal Protection Adjustment Range | 0.35-1.4 A |
Utilisation Category | AC-41 || AC-44 || AC-43 |
Depth | 60 mm |
Control Circuit Voltage Limits | 20 to 26.5 V AC 24 V in operation || 14.5 V AC 24 V drop-out |
Ambient Air Temperature For Operation | -25-70°C |
Reset | manual reset |
Compatibility Code | LUCC |
Device Short Name | LUCC |
Motor Power Kw | 0.09 kW 400 to 440 V AC 50/60 Hz 1 phase |
Operating Time | 35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB12 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
Reset Type | Manual |
Maximum Operating Temperature | 158 Degrees F |
Coil Voltage | 24V AC |
Minimum Operating Temperature | -13 Degrees F |
Terminal Connection Type | Wire Leads |
Maximum Rated Motor Current Adjustment | 1.4 A |
Compatible with Series | TeSys Ultra |
Maximum Voltage Rating | 690V AC |
Minumum Rated Motor Current Adjustment | 0.35 A |
Compatible with Manufacturer Model Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
Rated Insulation Voltage | 690 V IEC 60947-6-2, 600 V UL 60947-4-1, 600 V CSA C22.2 No 60947-4-1 |
Rated Motor Current Adjustment Range | 0.35 to 1.4 A |
Main Function Available | Manual reset, Earth fault protection, Protection against phase failure and phase imbalance, Protection against overload and short-circuit |
Compatible Manufacturer Part Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Overload Module, 0.35 to 1.40A, 3P, 24VAC, SCHNEIDER ELECTRIC, Mfr# LUCC1XB
$149,99
Free shipping will be applied on orders over $50
Overload Module, Maximum Rated Motor Current Adjustment 1.4 A, Minumum Rated Motor Current Adjustment 0.35 A, Coil Voltage 24V AC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Single, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB63, 5AB64, 5AB65, 5AB67
9999 in stock
Must order in multiples of 1
Subtotal:
$149.99