Item | Overload Module |
Voltage | 24V AC |
Phase | Single |
Thermal Setting Range (A) | 1.25 to 5.00 |
For Use With | LUxB32, LUxS12, LUxS32 Power Bases, Mfr. Series LUxB12 |
Features | Earth Fault Protection |
Trip Class - Overload | 10 |
Reset Type - Relay | Manual |
Trip Class | 10 |
Current Range | 1.25 to 5.00A |
Standards | ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed |
Sensing Method | Electronic |
Number of Poles | 3 |
Resistance To Electrostatic Discharge | 8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2 |
Fire Resistance | 960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12 |
Height | 66 mm |
Control Circuit Voltage Limits | 20 to 26.5 V AC 24 V in operation || 14.5 V AC 24 V drop-out |
Safe Separation Of Circuit | 400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1 |
Resistance To Fast Transients | 2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4 |
Product Or Component Type | advanced control unit |
Load Type | single-phase motor |
Protective Treatment | TH IEC 60068 |
Immunity To Radioelectric Fields | 10 V IEC 61000-4-6 |
Operating Time | 35 ms opening with LUB12 control circuit || 35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB12 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit |
Utilisation Category | AC-44 || AC-43 || AC-41 |
Fixing Mode | plug-in front face) |
Device Application | motor control || motor protection |
Network Frequency | 40 to 60 Hz |
[Uc] Control Circuit Voltage | 24 V AC |
Product Specific Application | basic protection and advanced functions, communication |
Motor Power Kw | 0.55 kW 400 to 440 V AC 50/60 Hz 1 phase |
Vibration Resistance | 2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6 |
Heat Dissipation | 2-2 W control circuit with LUB12 || 3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38 |
Non-Dissipating Shock Wave | 1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2 |
Width | 45 mm |
Reset | manual reset |
Typical Current Consumption | 140 mA 24 V AC I maximum while closing with LUB12 || 220 mA 24 V AC I maximum while closing with LUB32 || 220 mA 24 V AC I maximum while closing with LUB38 || 70 mA 24 V AC I rms sealed with LUB12 || 90 mA 24 V AC I rms sealed with LUB32 || 90 mA 24 V AC I rms sealed with LUB38 |
Product Name | TeSys Ultra |
Tripping Threshold | 14.2 x Ir +/- 20 % |
Function Available | protection against overload and short-circuit || manual reset || earth fault protection || protection against phase failure and phase imbalance |
Ip Degree Of Protection | IP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1 |
Immunity To Microbreaks | 3 ms |
Product Certifications | CE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine |
Thermal Overload Class | class 10 40-60 Hz -25-55°C IEC 60947-6-2 || class 10 40-60 Hz -25-55°C UL 508 |
Ambient Air Temperature For Operation | -25-70°C |
Resistance To Radiated Fields | 10 V/m 3 IEC 61000-4-3 |
[Ui] Rated Insulation Voltage | 690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1 |
Compatibility Code | LUCC |
Shock Resistance | 10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27 |
Range | TeSys |
Operating Altitude | 6561.68 ft (2000 m) |
Depth | 60 mm |
[Ue] Rated Operational Voltage | 690 V AC |
Device Short Name | LUCC |
Product Compatibility | power base LUB12 || power base LUB32 || power base LUB38 || power base LUB120 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B12B || reversing contactor breaker LU2B32B |
Ambient Air Temperature For Storage | -40-85°C |
Thermal Protection Adjustment Range | 1.25-5 A |
Immunity To Voltage Dips | 70 % / 500 ms IEC 61000-4-11 |
[Uimp] Rated Impulse Withstand Voltage | 6 kV IEC 60947-6-2 |
Maximum Operating Temperature | 158 Degrees F |
Compatible with Series | TeSys Ultra |
Terminal Connection Type | Wire Leads |
Reset Type | Manual |
Maximum Rated Motor Current Adjustment | 5 A |
Minumum Rated Motor Current Adjustment | 1.25 A |
Coil Voltage | 24V AC |
Maximum Voltage Rating | 690V AC |
Compatible with Manufacturer Model Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
Minimum Operating Temperature | -13 Degrees F |
Compatible Manufacturer Part Number | LU2B12B, LU2B32B, LUB12, LUB120, LUB32, LUB320, LUB38, LUB380 |
Country of Origin (subject to change) | France |
Package Quantity | 1 |
Overload Module, 1.25 to 5A, Class 10, 3P, SCHNEIDER ELECTRIC, Mfr# LUCC05B
$149,99
Free shipping will be applied on orders over $50
Overload Module, Maximum Rated Motor Current Adjustment 5 A, Minumum Rated Motor Current Adjustment 1.25 A, Coil Voltage 24V AC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Single, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB63, 5AB64, 5AB65, 5AB67
9999 in stock
Must order in multiples of 1
Subtotal:
$149.99
You must be logged in to post a review.
Reviews
There are no reviews yet.