Overload Module, Maximum Rated Motor Current Adjustment 18 A, Minumum Rated Motor Current Adjustment 4.5 A, Coil Voltage 24V AC, Compatible with Series TeSys Ultra, Terminal Connection Type Wire Leads, Trip Class 10, Phase Three, Maximum Voltage Rating 690V AC, Reset Type Manual, Standards ASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed, Compatible with Grainger Part Number 5AB64, 5AB67

9999 in stock

Must order in multiples of 1
Subtotal:
$149.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LUCB18B
Availability: Ships in 9 days
SKU: GRG3086465 Category:
ItemOverload Module
Voltage24V AC
PhaseThree
Thermal Setting Range (A)4.50 to 18.00
For Use WithLUxS32 Power Bases, Mfr. Series LUxB32
Trip Class10
FeaturesEarth Fault Protection
Trip Class - Overload10
Current Range4.50 to 18.0A
Sensing MethodElectronic
Number of Poles3
Reset Type - RelayManual
StandardsASEFA, ATEX Compliant, CCC, CE, CSA, CSA C22.2, EAC, EN 60947-6-2, Green Premium RoHS/REACH, IEC 60947-6-2, UL Listed
Tripping Threshold14.2 x Ir +/- 20 %
Control Circuit Voltage Limits20 to 26.5 V AC 24 V in operation || 14.5 V AC 24 V drop-out
Width45 mm
Typical Current Consumption220 mA 24 V AC I maximum while closing with LUB32 || 220 mA 24 V AC I maximum while closing with LUB38 || 90 mA 24 V AC I rms sealed with LUB32 || 90 mA 24 V AC I rms sealed with LUB38
[Ui] Rated Insulation Voltage690 V IEC 60947-6-2 || 600 V UL 60947-4-1 || 600 V CSA C22.2 No 60947-4-1
Safe Separation Of Circuit400 V SELV between the control and auxiliary circuits IEC 60947-1 || 400 V SELV between the control or auxiliary circuit and the main circuit IEC 60947-1
Product Or Component Typeadvanced control unit
[Uc] Control Circuit Voltage24 V AC
Shock Resistance10 gn power poles open IEC 60068-2-27 || 15 gn power poles closed IEC 60068-2-27
Vibration Resistance2 gn 5-300 Hz power poles open IEC 60068-2-6 || 4 gn 5-300 Hz power poles closed IEC 60068-2-6
Load Type3-phase motor self-cooled
Depth60 mm
Device Short NameLUCB
Thermal Protection Adjustment Range4.5-18 A
RangeTeSys
Heat Dissipation3-3 W control circuit with LUB32 || 3-3 W control circuit with LUB38
Resistance To Fast Transients2 kV 3 serial link IEC 61000-4-4 || 4 kV 4 all circuits except for serial link IEC 61000-4-4
Non-Dissipating Shock Wave1 kV serial mode IEC 60947-6-2 || 2 kV common mode IEC 60947-6-2
Device Applicationmotor control || motor protection
Network Frequency40 to 60 Hz
[Ue] Rated Operational Voltage690 V AC
Operating Time35 ms opening with LUB32 control circuit || 35 ms opening with LUB38 control circuit || 70 ms closing with LUB32 control circuit || 70 ms closing with LUB38 control circuit
Resistance To Electrostatic Discharge8 kV 3 in open air IEC 61000-4-2 || 8 kV 4 on contact IEC 61000-4-2
Product Specific Applicationbasic protection and advanced functions, communication
Fixing Modeplug-in front face)
Phase Failure Sensitivityyes
Resistance To Radiated Fields10 V/m 3 IEC 61000-4-3
Protective TreatmentTH IEC 60068
[Uimp] Rated Impulse Withstand Voltage6 kV IEC 60947-6-2
Immunity To Microbreaks3 ms
Product Compatibilitypower base LUB32 || power base LUB38 || power base LUB320 || power base LUB380 || reversing contactor breaker LU2B32B
Ip Degree Of ProtectionIP20 front panel and wired terminals IEC 60947-1 || IP20 other faces IEC 60947-1 || IP40 front panel outside connection zone IEC 60947-1
Utilisation CategoryAC-43 || AC-44 || AC-41
Ambient Air Temperature For Storage-40-85°C
Ambient Air Temperature For Operation-25-70°C
Product NameTeSys Ultra
Product CertificationsCE || UL || CSA || CCC || EAC || ASEFA || ATEX || Marine
Immunity To Voltage Dips70 % / 500 ms IEC 61000-4-11
Height66 mm
Function Availableprotection against overload and short-circuit || protection against phase failure and phase imbalance || manual reset || earth fault protection
Operating Altitude6561.68 ft (2000 m)
Compatibility CodeLUCB
Resetmanual reset
Immunity To Radioelectric Fields10 V IEC 61000-4-6
Motor Power Kw7.5 kW 400 to 440 V AC 50/60 Hz || 9 kW 500 V AC 50/60 Hz || 15 kW 690 V AC 50/60 Hz
Thermal Overload Classclass 10 40-60 Hz -25-70°C IEC 60947-6-2 || class 10 40-60 Hz -25-70°C UL 508
Fire Resistance960°C parts supporting live components IEC 60695-2-12 || 650°C IEC 60695-2-12
Maximum Operating Temperature158 Degrees F
Compatible with SeriesTeSys Ultra
Compatible with Manufacturer Model NumberLU2B32B, LUB32, LUB320, LUB38, LUB380
Terminal Connection TypeWire Leads
Minimum Operating Temperature-13 Degrees F
Minumum Rated Motor Current Adjustment4.5 A
Maximum Voltage Rating690V AC
Maximum Rated Motor Current Adjustment18 A
Reset TypeManual
Coil Voltage24V AC
Compatible Manufacturer Part NumberLU2B32B, LUB32, LUB320, LUB38, LUB380
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#Overload Module
#4.50 to 18A
#24VAC
#SCHNEIDER ELECTRIC
#Mfr LUCB18B
#SCHNEIDER ELECTRIC
#GRG3086465
#mfr:LUCB18B
#part number:LUCB18B
#pn:LUCB18B
#part code:LUCB18B
#item number:LUCB18B
#product code:LUCB18B
#manufacturer number:LUCB18B
#manufacturers part number:LUCB18B
#mfn:LUCB18B

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!