IEC Magnetic Contactor, 3 Poles, 24 V DC, 9 A, Reversing: No, SCHNEIDER ELECTRIC, Mfr# LP1K0910BD3

$110,99

Free shipping will be applied on orders over $50

IEC Magnetic Contactor, Auxiliary Contact Form 1NO, NEMA Enclosure Rating No Enclosure, NEMA Size Not Applicable, Coil Voltage 24V DC, Number of Poles 3, Full Load Current - Inductive 9 A, Full Load Current - Resistive 20 A, Reversing Capability Non-Reversing, Overall Height 2.28 in, Overall Width 1.77 in, Terminal Connection Type Screw Clamp Terminals, Mounting Style DIN Rail, Plate, Series TeSys K, Number of Auxillary Contacts 1, Contactor Style IEC, Maximum Voltage Rating 690V AC

9999 in stock

Must order in multiples of 1
Subtotal:
$110.99
Final shipping and tax calculated in checkout
Brand Name: SCHNEIDER ELECTRIC
Mfr #: LP1K0910BD3
Availability: Ships in 5 days
SKU: GRG0849558 Category:

Analogues

Full Load Amps-Inductive9 A
ItemIEC Magnetic Contactor
Full Load Amps-Resistive20 A
Number of Poles3
Coil Volts24 V DC
ReversingNo
Height2.28 in
Width1.77 in
Depth2.24 in
Enclosure NEMA RatingNo Enclosure
Aux. Contact ConfigurationNone
Hz50/60
Auxiliary Contact Form1NO
SeriesTeSys K
Frame / Series / Class / CodeTeSys
NEMA SizeNot Applicable
StandardsCSA, UKCA, UL Listed
Net Weight0.225 kg
Tightening Torque0.8 to 1.3 Nm
FeaturesBuilt-In Bi-Directional Peak Limiting Diode Suppressor
Rated Breaking Capacity110 A @ 415V, 440V, 220 to 230V, 380 to 400 V, 80 A @ 500V, 70 A @ 660 to 690V
Rated Making Capacity110 A
Mechanical Durability10 Mcycles
Working Height6561.68 ft
ApplicationMotor Control, Resistive Load
Mounts OnPlate, Rail
Switching Voltage17 V (Signalling Circuit)
Fire RatingUL 94 V1, NF F 16-101, NF F 16-102
Operating Speed3600 cycles per hr
Fuse Amps25 A (Power Circuit), 10 A (Signalling Circuit)
Impedance3 mOhm
Impulse Withstand Voltage8 kV
Control Circuit Voltage LimitsOperational: 0.8 to 1.15 Uc (at 50°C), Drop-Out: 0.1 to 0.75 Uc (at 50°C)
Rated Insulation Volts600/690V
Overvoltage CategoryCAT III
Operating Time30 to 40 ms (Coil Energisation and NO Closing), 10 ms (Coil De-Energisation and NO Opening)
Environmental AttributesMercury Free, Toxic Heavy Metal Free
Thermal Amperage20 A (at 50°C Power Circuit), 10 A (at 50°C Signalling Circuit)
Switching Current5 mA (Signalling Circuit)
Electrical Durability1.3 Mcycles 9 A AC-3 Less than or Equal to 440 V, 1.3 Mcycles 9 A AC-3e Less than or Equal to 440 V, 0.16 Mcycles 20 A AC-1 Less than or Equal to 690 V, 0.02 Mcycles 54 A AC-4 Less than or Equal to 440 V
Rated Voltage690V AC
Insulation Resistance RangeGreater Than 10 MOhms (Signalling Circuit)
Maximum Voltage Rating690V AC
Minimum Operating Temperature-13 Degrees F
Terminal Connection TypeScrew Clamp Terminals
Reversing CapabilityNon-Reversing
Number of Normally Open Main Contacts3
Contactor StyleIEC
Includes Auxiliary ContactsYes
Overall Depth2.24 in
Number of Auxillary Contacts1
NEMA Enclosure RatingNo Enclosure
Maximum Operating Temperature122 Degrees F
Mounting StyleDIN Rail, Plate
Coil Voltage24V DC
Full Load Current - Inductive9 A
Resistance PropertiesInsulation Resistant
NEMA Enclosure MaterialNot Applicable
Embedded Surge SuppressorYes
Overall Height2.28 in
Frequency50/60 Hz
Overall Width1.77 in
Full Load Current - Resistive20 A
Mechanical Operating Durability10,000,000
Rated Operational VoltagePower circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz, Signalling circuit Less than or Equal to 690 V AC Less than or Equal to 400 Hz
Contactor ApplicationResistive load, Motor control
Utilisation CategoryAC-3, AC-3e, AC-1, AC-4
Conventional Free Air Thermal Current20 A (at 140°F (60°C)) for power circuit, 10 A (at 122°F (50°C)) for signalling circuit
Ambient Air Temperature For Storage-58 to 176°F (-50 to 80°C)
Inrush Power in W3 W 68°F (20°C))
Auxiliary Contact Composition1 NO
Maximum Operating Rate3600 cyc/h
Associated Fuse Rating25 A gG at Less than or Equal to 440 V for power circuit, 25 A aM for power circuit, 10 A gG for signalling circuit conforming to IEC 60947, 10 A gG for signalling circuit conforming to VDE 0660
Average Impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Rated Operational Current9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3 for power circuit, 9 A (at Less than 140°F (60°C)) at Less than or Equal to 440 V AC AC-3e for power circuit, 20 A (at Less than 140°F (60°C)) at Less than or Equal to 690 V AC AC-1 for power circuit
Minimum Switching Current5 mA for signalling circuit
Power Pole Contact Composition3 NO
Connections - Terminalsscrew clamp terminals 1 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 1 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 1 0.00 to 0.00 in? (0.34 to 2.5 mm?)flexible with cable end, screw clamp terminals 2 0.00 to 0.01 in? (1.5 to 4 mm?)solid, screw clamp terminals 2 0.00 to 0.01 in? (0.75 to 4 mm?)flexible without cable end, screw clamp terminals 2 0.00 to 0.00 in? (0.34 to 1.5 mm?)flexible with cable end, Power circuit screw clamp terminals 2 0.00 in? (1.5 mm?)flexible with cable end
Operating Altitude6561.68 ft (2000 m) without derating
Rated Insulation VoltagePower circuit 600 V UL 508, Power circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-4-1, Signalling circuit 690 V IEC 60947-5-1, Signalling circuit 600 V UL 508, Power circuit 600 V CSA C22.2 No 14, Signalling circuit 600 V CSA C22.2 No 14
Coil TechnologyBuilt-in bidirectional peak limiting diode suppressor
Ambient Air Temperature For Operation-13 to 122°F (-25 to 50°C)
Heat Dissipation1.3 W
Safety Reliability LevelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1
Motor Power KW2.2 kW 220 to 230 V AC 50/60 Hz AC-3, 4 kW 380 to 415 V AC 50/60 Hz AC-3, 4 kW 440/690 V AC 50/60 Hz AC-3, 2.2 kW 220 to 230 V AC 50/60 Hz AC-3e, 4 kW 380 to 415 V AC 50/60 Hz AC-3e, 4 kW 440/690 V AC 50/60 Hz AC-3e, 2.2 kW 220 to 230 V AC 50/60 Hz AC-4, 4 kW 380 to 415 V AC 50/60 Hz AC-4, 4 kW 440/690 V AC 50/60 Hz AC-4
Rated Short Time Withstand Current90 A 122°F (50°C) - 1 s for power circuit, 85 A 122°F (50°C) - 5 s for power circuit, 80 A 122°F (50°C) - 10 s for power circuit, 60 A 122°F (50°C) - 30 s for power circuit, 45 A 122°F (50°C) - 1 min for power circuit, 40 A 122°F (50°C) - 3 min for power circuit, 20 A 122°F (50°C) - Greater than or Equal to 15 min for power circuit, 80 A - 1 s for signalling circuit, 90 A - 500 ms for signalling circuit, 110 A - 100 ms for signalling circuit
Auxiliary Contacts TypeInstantaneous 1 NO
Control Circuit TypeDC standard
Poles Description3P
IP Degree Of ProtectionIP2X
Product CertificationsCB Scheme, CCC, UL, CSA, EAC, CE, UKCA
Insulation ResistanceGreater than 10 MOhm for signalling circuit
Minimum Switching Voltage17 V for signalling circuit
Mounting SupportPlate, Rail
Flame RetardanceV1 conforming to UL 94, Requirement 2 conforming to NF F 16-101, Requirement 2 conforming to NF F 16-102
Hold-In Power Consumption in W3 W 68°F (20°C)
Product Or Component TypeContactor
IRMS Rated Making Capacity110 A AC for power circuit conforming to IEC 60947, 110 A AC for signalling circuit conforming to IEC 60947
Country of Origin (subject to change)France
Package Quantity1
TAGS:
#IEC Magnetic Contactor
#3 Poles
#24 V DC
#9 A
#Reversing: No
#SCHNEIDER ELECTRIC
#Mfr LP1K0910BD3
#SCHNEIDER ELECTRIC
#GRG0849558
#mfr:LP1K0910BD3
#part number:LP1K0910BD3
#pn:LP1K0910BD3
#part code:LP1K0910BD3
#item number:LP1K0910BD3
#product code:LP1K0910BD3
#manufacturer number:LP1K0910BD3
#manufacturers part number:LP1K0910BD3
#mfn:LP1K0910BD3

Reviews

There are no reviews yet.

Add a review
You have not viewed any product yet!